Isle Royale Wood Stove

B. Clearances To Combustibles (UL And ULC)

B

A

C

 

 

 

D

E

F

 

 

F

 

E

H

Ceiling G

I

8 in. max

J

J*

C

L

26-7/16 in.

I** (672mm)

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)

NOTE: “A”, “C” and “F” Dimensions are to the inside diameter of the flue collar.

 

A

B

C

D

E

F

G

H

I

FOR TOP VENT INSTALLATIONS:

 

 

 

 

 

 

 

SINGLE WALL PIPE

15 (381)

16 (406)

33 (838)

22 (558)

22 (558)

28 (711)

53 (1346)

18 (457)

16 (406)

DOUBLE WALL PIPE

13 (333)

14 (356)

29 (737)

18 (457)

6 (153)

12 (305)

53 (1346)

18 (457)

14 (356)

INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL 103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove shall be no more than 48 inch(1220mm). Please refer to the clearances below for minimum Alcove height requirements to top of unit.

DOUBLE WALL PIPE 13 (333) 14 (356)

29 (737)

18 (457)

N/A

N/A

53 (1346) 18 (457) 14 (356)

F

OR

R

EAR

VE

NT

I

NS

TAL

LATIO

NS:

IN A MASONRY FIREPLACE OR THROUGH THE WALL: Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL 103HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Additonal specifications include a maximum 8 inch (203mm) deep mantel without heat shield and the following clearances.

A

B

C

D

E

F

G

H

I

 

J

N/A

(N/A)

33 (838)

22 (558)

N/A

N/A

53 (1346)

N/A

14 (356)

9** (229)

36

(914) mantel

 

 

 

 

 

 

 

 

0 (00) In

Masonry Wall

14

(356)* mantel

*(J mantel) with shield spaced 1 inch (25mm) away from bottom mantel surface.

**(I) With 52 inch (1321mm) high and 42 inch (1067mm) wide wall protection spaced 1 inch (25mm) from combustible surface. NOTE: Wall protector must be a minimum of 24 gauge sheet metal with a 1 inch (25mm) air space between sheet metal and combustible wall. Sheet metal may then be covered with brick or tile.

Page 10

250-5763E

November 22, 2011

 

Image 10
Contents MBK PMH Non-Catalytic, Top-load, Wood HeaterHot glass will cause burns Isle Royale Wood Stove Welcome to the Quadra-Fire FamilyTable of Contents BTU & Effi ciency Specifi cations Isle Royale Wood Stove Listing and Code ApprovalsAppliance Certifi cation Mobile Home ApprovedFire Safety Isle Royale Wood Stove Getting StartedNegative Pressure WindwardTools And Supplies Needed Flue Draft ConsiderationsVenting Systems Inspect Appliance & Components and Pre-Burn Check ListTypical Stove Systems Masonry ChimneyIsle Royale Wood Stove Dimensions and Clearances Appliance DimensionsFor TOP Vent Installations Clearances To Combustibles UL And ULCSee Figure Isle Royale Wood Stove Installation ConsiderationsHearth Protection Requirements USA Required Canada RecommendedReversible Flue Collar Converting Collar For Rear Vent InstallationRear Flue Defl ector Cover Plate Installation Of Optional Blower Outside Air Kit InstallationItems Needed for Installation 4 inch 102mm diameter Venting Components Isle Royale Wood Stove Chimney RequirementsChimney Systems Air Clearances ComponentsInstructions Masonry Chimney Liner Chimney Height / Rise and RunInstalling Chimney Components Masonry Chimney Liner ContdChimney Termination Requirements RuleIsle Royale Wood Stove Mobile Home Installation 629M, Standard for Factory Built ChimneysAdjusting The Blower Speed Control Door Handle Assembly Isle Royale Wood Stove Appliance Set-UpOver-Firing Your Appliance Wood Selection and Storage Symptoms of Over-FiringIsle Royale Wood Stove Operating Instructions Fire RiskKindling or First Stage Burning ProcessSecond Stage Combustible/Non-Combustible Materials Air ControlsOperating The Top Loading Option Heat Output SettingsBurn Rates Building a Fire Opacity Smoke Frequently Asked QuestionsOptional Blower Operating Instructions Clear SpaceGeneral Maintenance Glass Cleaning Frequency As desired Cleaning Plated SurfacesDisposal of Ashes Glass Replacement Inspect Firebrick & Replacement InstructionsAppliance Inspection Routine Quick Reference Maintenance Guide MonthlyIsle Royale Wood Stove Troubleshooting Guide Start Fire Problems Possible Cause SolutionNon-Catalytic, Top-Load Service PartsExploded Drawing Part number list on following Wood StoveStocked Service Parts and Accessories#9 Baffl e Assembly At DepotStocked at Depot #13 Door Assembly 13.9 13.1 13.8 13.2 13.7 13.4 13.3 13.5 13.6Brick, Uncut Must specify size when ordering Stocked at Depot #19 Brick Assembly19.5 19.3 Accessories Service And Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Isle Royale Wood Stove Contact Information