Isle Royale Wood Stove

1Listing and Code Approvals

A.Appliance Certifi cation

Model:

Isle Royale

 

 

Laboratory:

OMNI Test Laboratories, Inc.

 

 

Report No & Date:

061-S-18-2

 

 

Type:

Listed Room Heater, Solid Fuel Type

 

 

Standard:

UL1482, UL737, ULC S627-93

 

and (UM) 84-HUD, Mobile Home

 

Approved.

 

 

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the UL1482, UL737, (UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-93 and CAN/CSA-B365 Installation Codes in Canada.

D. BTU & Effi ciency Specifi cations

EPA Certifi ed:

2.9 grams per hour

 

 

Effi ciency:

76.5%

 

 

BTU Output:

11,500 to 46,000

 

 

Heating Capacity:

2,040 to 3,500 sq ft

 

depending on climate zone

 

 

Vent Size:

6 inches

 

 

Firebox Size:

3.0 cubic feet

 

 

Max Wood Length:

22 inches

 

 

Fuel:

Cord Wood

 

 

Shipping Weight:

480 lbs

The Quadra-Fire Isle Royale Wood Stove meets the U.S. Environmental Protection Agency’s 1990 particulate emis- sion standards.

B. Mobile Home Approved

This appliance is approved for mobile home installa- tions when not installed in a sleeping room and when an outside combustion air inlet is provided.

The structural integrity of the mobile home fl oor, ceil- ing, and walls must be maintained.

The appliance must be properly grounded to the frame of the mobile home with #8 copper ground wire, and use only listed double-wall connector pipe.

Outside Air Kit, part 831-1780 must be installed in a mobile home installation.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance.

Modifi cation of the appliance.

Installation other than as instructed by Hearth & Home Technologies.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Operating appliance without fully assembling all components.

Operating appliance without legs attached (if supplied with unit).

Do NOT Overfi re - If appliance or chimney connector glows, you are overfi ring.

Any such action that may cause a fi re hazard.

C. Glass Specifi cations

This stove is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

Quadra-Fire is a registered trademark of Hearth & Home Technologies.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

For assistance or additional information, consult a qualifi ed installer, service agency or your dealer.

NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifi cations and/or price without notice.

Page 4

250-5763E

November 22, 2011

 

Image 4
Contents MBK PMH Non-Catalytic, Top-load, Wood HeaterHot glass will cause burns Isle Royale Wood Stove Welcome to the Quadra-Fire FamilyTable of Contents Isle Royale Wood Stove Listing and Code Approvals Appliance Certifi cationBTU & Effi ciency Specifi cations Mobile Home ApprovedFire Safety Isle Royale Wood Stove Getting StartedNegative Pressure WindwardFlue Draft Considerations Venting SystemsTools And Supplies Needed Inspect Appliance & Components and Pre-Burn Check ListTypical Stove Systems Masonry ChimneyIsle Royale Wood Stove Dimensions and Clearances Appliance DimensionsFor TOP Vent Installations Clearances To Combustibles UL And ULCIsle Royale Wood Stove Installation Considerations Hearth Protection RequirementsSee Figure USA Required Canada RecommendedReversible Flue Collar Converting Collar For Rear Vent InstallationRear Flue Defl ector Cover Plate Installation Of Optional Blower Outside Air Kit InstallationItems Needed for Installation 4 inch 102mm diameter Venting Components Isle Royale Wood Stove Chimney RequirementsChimney Systems Air Clearances ComponentsInstructions Masonry Chimney Liner Chimney Height / Rise and RunInstalling Chimney Components Masonry Chimney Liner ContdChimney Termination Requirements RuleIsle Royale Wood Stove Mobile Home Installation 629M, Standard for Factory Built ChimneysAdjusting The Blower Speed Control Door Handle Assembly Isle Royale Wood Stove Appliance Set-UpSymptoms of Over-Firing Isle Royale Wood Stove Operating InstructionsOver-Firing Your Appliance Wood Selection and Storage Fire RiskKindling or First Stage Burning ProcessSecond Stage Combustible/Non-Combustible Materials Air ControlsOperating The Top Loading Option Heat Output SettingsBurn Rates Building a Fire Frequently Asked Questions Optional Blower Operating InstructionsOpacity Smoke Clear SpaceGeneral Maintenance Glass Cleaning Frequency As desired Cleaning Plated SurfacesDisposal of Ashes Glass Replacement Inspect Firebrick & Replacement InstructionsAppliance Inspection Routine Quick Reference Maintenance Guide MonthlyIsle Royale Wood Stove Troubleshooting Guide Start Fire Problems Possible Cause SolutionService Parts Exploded Drawing Part number list on followingNon-Catalytic, Top-Load Wood StoveService Parts and Accessories #9 Baffl e AssemblyStocked At DepotStocked at Depot #13 Door Assembly 13.9 13.1 13.8 13.2 13.7 13.4 13.3 13.5 13.6Brick, Uncut Must specify size when ordering Stocked at Depot #19 Brick Assembly19.5 19.3 Accessories Service And Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Isle Royale Wood Stove Contact Information