R
Isle Royale Wood Stove
5Chimney Requirements
A. Venting Components
Chimney Connector:
It is also known as fl ue pipe or stove pipe. The chimney connector joins the stove to the chimney. It must be a 6 inch (152mm) minimum diameter 24 gauge mild steel black or 26 gauge blued steel, or an approved
Thimble:
A manufactured or
Chimney:
The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements specifi ed in Section 5B.
Listed Termination Cap |
| |
Roof Brace (if required) |
| |
| Storm Collar | |
| Flashing | |
Trim Collar on | Listed Chimney | |
| ||
Inside Wall | Insulated " T " | |
| ||
Chimney | Wall Support | |
Connector | ||
| ||
| Thimble | |
Floor |
| |
Protector |
|
Figure 14.1 Prefabricated Exterior Chimney
B. Chimney Systems
Prefabricated Metal Chimney
•Must be minimum 6 inch (152mm) diameter (ID) high temperature chimney listed to UL 103 HT (2100oF) or ULC S629M.
•Must use components required by the manufacturer for installation.
•Must maintain clearances required by the manufacturer for installation.
•Refer to manufacturers instructions for installation.
NOTE: In Canada when using a
FACTORY-BUILT CHIMNEYS.
Listed Termination Cap |
Storm Collar |
Flashing |
Listed Chimney |
Ceiling Support |
Chimney |
Connector |
Floor |
Protector |
Figure 14.2 - Prefabricated Interior Chimney