Operation Details
1. Time Delay Safety Control
3min | The compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle. |
| (Protection of compressor) |
3sec | The indoor fan is ceased for 3 seconds to prevent relay noise. |
| (Protection of fan relay and micro chip) |
30sec The
2. Airflow Direction Control
This function is to swing the louver left and right automatically and to set it at the desired position.
The procedure is as the following.
1st : Press the ON/OFF Button to operate the product.
2nd : Press the Airflow Direction Control Button to swing the louver left and right automatically. (Remote controller)
3rd : Repress the Airflow Direction Control Button to set the louver as the desired position. (Remote controller)
3. Cooling Mode Operation
When selecting the Cooling( ) Mode Operation, the unit will operate according to the setting by the controller and the operation diagram is as following.
Intake Air temp.
Setting Temp. +1°C(1.8°F) |
|
|
|
|
| |
(Compressor ON) |
|
|
|
|
| |
Setting Temp. |
|
|
|
|
| |
(Compressor OFF) |
| More than |
| More than |
| |
|
|
|
| |||
|
| 3 minutes |
| 3 minutes |
| |
Indoor Fan Speed | Selecting | Selecting | Selecting | Selecting | Selecting | |
fan speed | fan speed | fan speed | fan speed | fan speed | ||
| ||||||
Compressor | ON | OFF | ON | OFF | ON |
4. Off Timer Function
This function is to set the time of stopping the unit operation.
The procedure is as the following.
1st: Press the timer set button on the Remocon.
2nd: The buzzer sounds and then the display window shows the | .... |
-The
-If you select ' ', the
-During