2. Indoor Unit installation
The mounting floor should be strong and solid enough to prevent it from vibration.
Drill the piping hole with 2.8 inch diameter hole- core drill at either the right or the left of indoor unit. The hole should be sightly slant to the outdoor side.
200mm(7.9 inch)
70mm(2.8 inch) | inch) | 70mm(2.8 inch) |
| ||
| 90mm(3.5 | |
|
|
Wall
Core Drill
INSIDEOUTSIDE
3. Outdoor unit Installation
Install the outdoor unit on the concrete or any solid base securely and horizontally by securing it with bolts (Ø12mm(0.5inch)) and nuts.
If there is any vibration transmitted to the building, mount the rubber underneath the outdoor unit.
4. Refrigerant amount
Before shipment, this air conditioner is filled with the rated amount of refrigerant including additional amount required for
MODEL (BTU/h) | REFRIGERANT CHARGE |
|
|
48k | 40g/m(1.41oz/m) |
|
|
30k | 30g/m(1.06oz/m) |
|
|
Example)
In case of 15m(49ft) long
48k :
Plastic tube (Bushing)
Wall
Tilt
Cut if necessary
More than 15mm(0.6 inch)
Insert the plastic tube through the hole.
Cut the extruded outside part of the plastic tube, if necessary.