State Industries 650A, 540A, 740A warranty For Your Safety Read Before Lighting

Page 22

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance is equipped with an ignition device which automatically lights the burner.

Do NOT try to light burner by hand.

B.BEFORE LIGHTING: Smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

E.Do not operate appliance unless unit is filled with water and inlet lines are fully open.

FIGURE “A”

FIGURE “B”

 

 

 

“OFF POSITION”

“ON POSITION”

 

 

 

 

 

 

 

 

 

 

OPERATING INSTRUCTIONS

 

 

 

1.

STOP! Read the safety information above on this

8.

Turn on all electric power to the appliance.

 

label.

 

 

 

9.

Set thermostat to desired setting.

2.

Remove appliance thermostat cover. Rotate thermostat

10.

Turn switch to “ON” position.

 

dial counterclockwise

to lowest setting.

 

 

 

 

 

 

3.

Turn off all electric power to the appliance.

 

11.

Heater will automatically begin operation. Blower motor

 

 

will run approximately 40 seconds, then pilot gas valve

 

 

 

 

 

 

4.

This appliance is equipped an ignition device which

 

will open. Upon confirming the pilot flame the main gas

 

automatically lights the burner. Do NOT try to light the

 

valve will open and the heater will operate in heating

 

burner by hand.

 

 

 

 

mode. Reference “Sequence of Operation” section of

5.

Refer to diagrams above. Turn top knob of gas control

 

manual for details.

 

 

 

12. Heater is equipped with an ignition module which locks out

 

clockwise to “OFF” position (Figure A).

 

6.

Wait five (5) minutes to clear out any gas. If you then smell

 

after one (1) unsuccessful ignition attempt. Blower motor

 

will continue to run. If lockout occurs, turn burner switch to

 

gas,

 

 

 

 

“OFF” position for at least one minute, then turn the switch

 

STOP! Follow “B” in the safety information above

 

back to “ON”. Heater will automatically begin operation.

 

 

 

 

 

 

 

on this label. If you don’t smell gas, go to next

13.

Replace thermostat control cover.

 

step.

 

 

 

 

 

 

 

 

7.

Turn top knob of gas control counterclockwise

to

14.

If the appliance will not operate, follow the instructions

 

“TO TURN OFF GAS APPLIANCE” and call your service

 

“ON” (Figure B).

 

 

 

 

technician or gas supplier.

 

 

 

 

 

 

TO TURN OFF GAS TO APPLIANCE

 

1.

Remove thermostat control cover.

 

4.

Turn off all electric power to the appliance if service is

 

 

 

 

 

 

to be performed.

 

 

 

2.

Set thermostat to lowest setting.

 

5.

Turn top knob of gas control to the “OFF” position. Refer

 

 

 

 

 

 

to Step 5 of ‘OPERATING INSTRUCTION” above.

3.

Turn burner switch to “OFF”.

 

6.

Replace thermostat control cover.

 

 

 

 

 

 

 

 

 

 

22

Image 22
Contents Models GPG/GPV-540A, 650A and 740A ROUGH-IN Dimensions ForewordTable of Contents General Safety InformationFeatures Extended NON-USE PeriodsRequired Ability Installation InstructionsDishwashing Machine Requirement UncratingAIR Requirements Hard WaterClearances VentingHorizontal SIDE-WALL Venting For GPV Models Barometric Draft Control AssemblyVertical Venting for GPG Models Vent ConnectionsVent System Installation Vent Terminal LOCATIONS-EXHAUSTDirect Venting for GPV Models Vent Terminal LOCATIONS-INTAKEDirect Vent System Installation GAS Piping Vent Diameter GPV -540A, 650A & 740AGAS Valves GAS Meter Size City Gases onlyGAS Pressure Regulation Sources of Ignition for this PurposeRelief Valve Water Line ConnectionsSystem Connections Installation Diagrams Circulating Pump Wiring DiagramWiring Diagram for Tempered Water Loop if Used Circulating Pump Wiring Diagram Page Manifold Kits Purging Heater WiringStart UP FillingPage Page For Your Safety Read Before Lighting Sequence of Operation Page Premix LOW NOx Burner Exploded View for GPG Models Premix LOW NOx Burner Exploded View for GPV Models Maintenance General InformationSediment Removal DrainingLime Scale Removal Checklist and Service Water Heater Makes Sounds TroubleshootingWater is TOO HOT Water Leakage is SuspectedMotor will not RUN Burner Lockout Once in a WhileNoisy Burner Operation GAS Fails to Shut OFFModel GPG/GPV Limited Warranty Replacement Parts List Part List for GPG Burner Assembly Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

740A, 540A, 650A specifications

State Industries is well-known for its high-quality water heating solutions, and among its product lineup, the 650A, 540A, and 740A models stand out for their advanced features and technology. Each of these models cater to different needs, making them versatile choices for both residential and commercial applications.

The State Industries 650A model is designed for efficient hot water delivery, featuring a powerful heating element that ensures rapid heating of water. It has an impressive recovery rate, which is crucial for homes with higher hot water demands. The 650A also integrates a robust insulation system that minimizes heat loss, ensuring energy efficiency. With a capacity of 65 gallons, it is perfectly suited for larger households or small commercial setups.

Next in the lineup is the 540A model, which strikes a balance between performance and size. With a capacity of 54 gallons, this model is ideal for medium-sized homes. It employs advanced heating technology that significantly reduces energy consumption while providing consistent hot water supply. The 540A is also equipped with a user-friendly digital interface that allows homeowners to monitor temperatures and set preferences with ease. Additionally, it features durable construction materials, promoting longevity and reliability in everyday use.

Finally, the 740A model offers the highest capacity of the three, boasting an extensive 74-gallon storage tank. This model is particularly advantageous for larger families or businesses that require substantial hot water availability. Similar to the 650A, the 740A employs advanced insulation techniques, ensuring that energy loss is minimized. It's also equipped with smart technology that allows for remote monitoring and adjustment, providing convenience for busy homeowners.

All three models utilize high-efficiency heating elements and are designed for easy installation and maintenance. They incorporate safety features such as temperature and pressure relief valves to ensure safe operation. Moreover, these units are built to meet or exceed industry standards, making them a reliable choice for anyone looking to invest in a hot water solution. Overall, State Industries continues to lead the market with innovative products like the 650A, 540A, and 740A, catering to diverse hot water needs with efficiency and reliability.