State Industries 540A, 650A, 740A warranty Wiring Diagram for Tempered Water Loop if Used

Page 15

TWO TEMPERATURE - ONE HEATER HIGH TEMPERATURE

WITH OR WITHOUT BUILDING RECIRCULATION

*PIPE RELIEF VALVE TO OPEN DRAIN

NOTE: I F T E M P E R E D W AT E R I S RECIRCULATED, RETURN LINE SHOULD BE CONNECTED AT POINT “A”.

INSTALL IN ACCORDANCE WITH LOCAL

CODES

DANGER

T E M P ERAT URE SETTING SHOULD

NOT EXCEED SAFE TEMPERATURE AT

FIXTURES. SEE WATER TEMPERATURE

CONTROL WARNING ON PAGE 23. IF

HIGHER PREHEAT TEMPERATURES ARE

NECESSARY TO OBTAIN ADEQUATE

BOOSTER OUTPUT, ADD AN ANTI-SCALD

VALVE FOR HOT WATER SUPPLIED TO

FIXTURES.

CAUTION: IF BUILDING COLD WATER

SUPPLY HAS A BACKFLOW PREVENTER,

CHECK VALVE OR WATER METER WITH

CHECK VALVE, PROVISIONS FOR THERMAL

EXPANSION OF WATER IN THE HOT WATER

SYSTEM MUST BE PROVIDED.

WIRING DIAGRAM FOR TEMPERED WATER LOOP (IF USED)

CIRCULATING PUMP WIRING DIAGRAM

TWO TEMPERATURE - TWO HEATERS HIGH TEMPERATURE

WITH OR WITHOUT BUILDING RECIRCULATION

15

Image 15 Contents
Models GPG/GPV-540A, 650A and 740A Foreword ROUGH-IN DimensionsGeneral Safety Information Table of ContentsExtended NON-USE Periods FeaturesUncrating Installation InstructionsDishwashing Machine Requirement Required AbilityVenting Hard WaterClearances AIR RequirementsVent Connections Barometric Draft Control AssemblyVertical Venting for GPG Models Horizontal SIDE-WALL Venting For GPV ModelsVent Terminal LOCATIONS-EXHAUST Vent System InstallationVent Terminal LOCATIONS-INTAKE Direct Venting for GPV ModelsDirect Vent System Installation Vent Diameter GPV -540A, 650A & 740A GAS PipingSources of Ignition for this Purpose GAS Meter Size City Gases onlyGAS Pressure Regulation GAS ValvesWater Line Connections Relief ValveSystem Connections Circulating Pump Wiring Diagram Installation DiagramsWiring Diagram for Tempered Water Loop if Used Circulating Pump Wiring Diagram Page Manifold Kits Filling Heater WiringStart UP PurgingPage Page For Your Safety Read Before Lighting Sequence of Operation Page Premix LOW NOx Burner Exploded View for GPG Models Premix LOW NOx Burner Exploded View for GPV Models General Information MaintenanceDraining Sediment RemovalLime Scale Removal Checklist and Service Water Leakage is Suspected TroubleshootingWater is TOO HOT Water Heater Makes SoundsBurner Lockout Once in a While Motor will not RUNGAS Fails to Shut OFF Noisy Burner OperationModel GPG/GPV Limited Warranty Replacement Parts List Part List for GPG Burner Assembly Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax