Sterling Plumbing 882.00253.00 Setup, Connecting the Control Panel to Vacuum Hoppers

Page 15

Connecting the Control Panel to Vacuum Hoppers

Note: Wire size depends on control voltage, distance, number of vacuum hoppers, and the number of wires in each raceway. Consult a qualified electrician.

1.On 24 VDC control voltage systems, run a common +24 VDC wire and a common 0 (zero) VDC wire from the controller to each vacuum hopper in the system.

2.Run two wires to each vacuum hopper: one each from the controller to the Bin- Full switch (LS) and to the Atmospheric/Sequence-T solenoid (SOL) valve.

3.Make sure that the solenoid and the proximity switch (if supplied) on vacuum hoppers are the same voltage (24 VDC) as the control panel voltage. Consult the control panel serial tag and the solenoid valve nameplates.

4.Properly ground each hopper to reduce static build up generated by material conveying.

Connecting the Control Panel to the Pump Package

1.Wire the pump package motor starter coil (M) to the terminal provided in the control panel enclosure.

2.Wire the pump package vacuum relief valve solenoid (SOL A) to the terminal provided in the control panel enclosure.

3.Wire the pump package vacuum switch (VS) to the terminal located in the control panel enclosure.

4.On 24 VDC control voltage systems, run a common +24 VDC wire and a common 0 (zero) VDC wire from the controller to each pump package in the system.

3-4 Setup

This section provides the procedures for configuring your 4-pump, 38-station controller.

Configuration of your controller includes setting the number of stations and pumps, setting variables such as convey time and blow-back interval, and setting up passwords. We recommend that you carry out these procedures in the order given here.

Note: Before carrying out these procedures, install all equipment as described in this section and in the manual SPD/SPC Series Conveying Systems.

4 –Pump 38-Station Controllers

Chapter 3: Installation

14 of 44

Image 15
Contents SCC 4-Pump 38-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Safety How to Use This ManualSafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves General Responsibility ResponsibilityMaintenance Responsibility Reporting a Safety DefectOperator Responsibility Functional Description Models Covered in This ManualGeneral Description Controller Features Standard FeaturesMechanical Features Electrical FeaturesFail Safe Operation Optional FeaturesSafety Devices and Interlocks Safety Circuit StandardsSafety Device Lock-Outs Mounting the Control Panel InstallationMaking Control Panel Power Drop Wiring Connections UncratingSetup Connecting the Control Panel to Vacuum HoppersConnecting the Control Panel to the Pump Package Default Station Status Screen Before Setup Setting the Number of Stations and the Number of PumpsSystem Setup Screen Setting Up Alarm SilencesSetting Up Stations Setting Up Pump StagingStation Operator Screen Before Setup Pump Status Screen Setting Up PumpsSetup Password Finishing Setup Setting Up PasswordsOperator Password Initial Startup Reviewing Station Status OperationOverview Basic TasksColor Label Description Pump Status Screen During Operation Reviewing Pump StatusLogging On and Logging Off Password Entry ScreenStarting and Stopping the System Enabling and Disabling Stations and PumpsStation Operator Screen Reviewing and Adjusting Basic Station SettingsAdjusting Convey Time and Dump Delay Navigating among the Station Operator Screens Activating and Stopping Priority Convey for a StationReviewing and Resetting a Pump Hour Meter Adjusting Advanced SettingsTransfer To Standby Pump Screen Transferring Stations to a Standby PumpTransfer To Standby Pump Button Alarms Reviewing AlarmsSilencing Alarms Maintenance Options for Station Setup Configurable Settings# attempts before Name Description Options Default Special conveyAlarm No conveyIdle Time Options Options for Pump SetupTroubleshooting General TroubleshootingProblem Possible Cause Solution Alarm message Possible cause Station AlarmsPump Alarms System AlarmsWarranty AppendixOptional Components Drawings and Diagrams Spare Parts ListQuantity Part Number Description Returned Material Policy Safety Tag InformationWarranty Returns Controller Safety TagsTechnical Assistance Contact Information Controller Identification Serial Number Tag

882.00253.00 specifications

Sterling Plumbing has established a solid reputation in the plumbing industry, and their model 882.00253.00 is an exemplary product that showcases quality and innovation. This particular item is part of Sterling's commitment to providing reliable and stylish plumbing fixtures that meet the needs of modern homes.

One of the standout features of the Sterling Plumbing 882.00253.00 is its exceptional design. The product is crafted with sleek lines and a contemporary aesthetic, making it an ideal choice for various bathroom styles, from minimalistic to more traditional setups. The finish is not only visually appealing but also practical, as it resists tarnishing and corrosion, ensuring durability and longevity.

In addition to its attractive design, the 882.00253.00 includes advanced technologies that enhance its functionality. The model employs a user-friendly installation system, allowing for a smooth and hassle-free setup. Homeowners or contractors can easily install this fixture without the need for specialized tools, reducing labor costs and installation time.

Another key characteristic of this plumbing fixture is its water efficiency. The Sterling 882.00253.00 is engineered with advanced flow technologies that help conserve water without compromising performance. This eco-friendly feature is becoming increasingly important as more consumers look for ways to reduce their environmental footprint and lower utility bills.

The Sterling Plumbing model also boasts robust construction. Made from high-quality materials, it is designed to withstand everyday wear and tear in busy households. The sturdy components ensure a dependable performance throughout its lifespan, making it a wise investment for homeowners and builders alike.

Furthermore, the 882.00253.00 emphasizes user comfort and accessibility. The ergonomic design and intuitive controls make it easy to use for individuals of all ages, enhancing overall user satisfaction. Whether it’s for bathroom usage or other plumbing needs, this model does not fall short in delivering top-tier performance.

Overall, the Sterling Plumbing 882.00253.00 stands out as a remarkable fixture that blends aesthetic appeal with cutting-edge technologies and user-focused design. Its durability, efficiency, and modern styling make it a favorable option for consumers looking to upgrade their plumbing solutions. Investing in this model means choosing a reliable product that aligns with both functionality and contemporary design principles.