Sterling Plumbing 882.00253.00 specifications Options for Pump Setup, Idle Time Options

Page 39

6-2 Options for Pump Setup

Several of the items in this screen are not setup options but are instead intended for use during operation. These items (hour meter and transferring stations to a standby pump) are described in Chapter 4, which cover operation procedures.

Name

Description

Options

Default

Idle Time Options

 

 

 

1 Idle time

Length of time the pump continues to run unloaded

0–999 sec.

45 sec.

 

without demand from any station. After this time has

 

 

 

elapsed, the pump shuts down to save power and to

 

 

 

prevent wear on the pump.

 

 

 

Adjust this setting to fit the needs of your facility

 

 

 

in trading off the energy savings against the

 

 

 

costs associated with waiting for a pump to start

 

 

 

up when there is a demand for material.

 

 

Alarm Options

 

 

 

General Pump fault

The control has one input/pump that you can wire to

disabled,

disabled

 

generate alarms for situations of your choosing. For

enabled

 

 

example, you may have a sensor that turns on when

 

 

 

material reaches the top of a filter-chamber waste

 

 

 

bin. When this option is enabled, the controller issues

 

 

 

an alarm if the sensor wired to the input for Pump

 

 

 

Fault turns on.

 

 

 

Enable this option if and only if your facility has

 

 

 

installed a miscellaneous alarm on the input for

 

 

 

Pump Fault for this pump.

 

 

Pump Filter Cleaning Options

 

 

Vacuum pulsed filter

When this option is enabled, the controller

disabled,

disabled

cleaning

periodically sends compressed air backward through

vacuum pulse

 

(Compressed air filter

the pump’s air filter to dislodge accumulated dust and

enabled

 

cleaning)

debris.

comp air

 

 

Enable this option if and only if the pump has the

enabled

 

 

equipment for compressed-air filter cleaning.

 

 

Conveys before

Number of conveying cycles to stations between filter

1–99

5

cleaning

cleanings.

 

 

 

Adjust this setting based on experience. The more

 

 

 

dust and debris in your material line, the smaller this

 

 

 

number needs to be.

 

 

Cleaning pulses

Number of pulses of compressed air sent through the

1–99

5

 

pump’s filter during cleaning.

 

 

 

If filter-cleaning is not working as desired, the service

 

 

 

department may ask you to change this setting.

 

 

Pulse On time

Number of seconds that the air compressor remains

0–9.9 sec.

3.0 sec.

(Compressed air

on for each pulse during filter cleaning.

 

 

cleaning only)

If filter-cleaning is not working as desired, the service

 

 

 

department may ask you to change this setting.

 

 

Pulse Off time

Number of seconds between air pulses during filter

0–9.9 sec.

1.5 sec.

(Vacuum Pulse cleaning

cleaning.

 

 

only)

If filter-cleaning is not working as desired, the service

 

 

 

department may ask you to change this setting.

 

 

Vacuum time

Amount of time clearing valve is closed and vacuum

0-9.9 sec.

3.0 sec.

 

increases inside filter chamber.

 

 

Vacuum vent time

Amount of time clearing valve is open to allow air to

0-9.9 sec.

1.5 sec.

 

reverse flow through filter.

 

 

4 –Pump 38-Station Controllers

Chapter 6: Configurable Settings

38 of 44

Image 39
Contents SCC 4-Pump 38-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Safety How to Use This ManualSafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves General Responsibility ResponsibilityMaintenance Responsibility Reporting a Safety DefectOperator Responsibility Functional Description Models Covered in This ManualGeneral Description Controller Features Standard FeaturesMechanical Features Electrical FeaturesFail Safe Operation Optional FeaturesSafety Devices and Interlocks Safety Circuit StandardsSafety Device Lock-Outs Mounting the Control Panel InstallationMaking Control Panel Power Drop Wiring Connections UncratingSetup Connecting the Control Panel to Vacuum HoppersConnecting the Control Panel to the Pump Package Default Station Status Screen Before Setup Setting the Number of Stations and the Number of PumpsSystem Setup Screen Setting Up Alarm SilencesSetting Up Stations Setting Up Pump StagingStation Operator Screen Before Setup Pump Status Screen Setting Up PumpsSetup Password Finishing Setup Setting Up PasswordsOperator Password Initial Startup Reviewing Station Status OperationOverview Basic TasksColor Label Description Pump Status Screen During Operation Reviewing Pump StatusLogging On and Logging Off Password Entry ScreenStarting and Stopping the System Enabling and Disabling Stations and PumpsStation Operator Screen Reviewing and Adjusting Basic Station SettingsAdjusting Convey Time and Dump Delay Navigating among the Station Operator Screens Activating and Stopping Priority Convey for a StationReviewing and Resetting a Pump Hour Meter Adjusting Advanced SettingsTransfer To Standby Pump Screen Transferring Stations to a Standby PumpTransfer To Standby Pump Button Alarms Reviewing AlarmsSilencing Alarms Maintenance Options for Station Setup Configurable Settings# attempts before Name Description Options Default Special conveyAlarm No conveyIdle Time Options Options for Pump SetupTroubleshooting General TroubleshootingProblem Possible Cause Solution Alarm message Possible cause Station AlarmsPump Alarms System AlarmsWarranty AppendixOptional Components Drawings and Diagrams Spare Parts ListQuantity Part Number Description Returned Material Policy Safety Tag InformationWarranty Returns Controller Safety TagsTechnical Assistance Contact Information Controller Identification Serial Number Tag

882.00253.00 specifications

Sterling Plumbing has established a solid reputation in the plumbing industry, and their model 882.00253.00 is an exemplary product that showcases quality and innovation. This particular item is part of Sterling's commitment to providing reliable and stylish plumbing fixtures that meet the needs of modern homes.

One of the standout features of the Sterling Plumbing 882.00253.00 is its exceptional design. The product is crafted with sleek lines and a contemporary aesthetic, making it an ideal choice for various bathroom styles, from minimalistic to more traditional setups. The finish is not only visually appealing but also practical, as it resists tarnishing and corrosion, ensuring durability and longevity.

In addition to its attractive design, the 882.00253.00 includes advanced technologies that enhance its functionality. The model employs a user-friendly installation system, allowing for a smooth and hassle-free setup. Homeowners or contractors can easily install this fixture without the need for specialized tools, reducing labor costs and installation time.

Another key characteristic of this plumbing fixture is its water efficiency. The Sterling 882.00253.00 is engineered with advanced flow technologies that help conserve water without compromising performance. This eco-friendly feature is becoming increasingly important as more consumers look for ways to reduce their environmental footprint and lower utility bills.

The Sterling Plumbing model also boasts robust construction. Made from high-quality materials, it is designed to withstand everyday wear and tear in busy households. The sturdy components ensure a dependable performance throughout its lifespan, making it a wise investment for homeowners and builders alike.

Furthermore, the 882.00253.00 emphasizes user comfort and accessibility. The ergonomic design and intuitive controls make it easy to use for individuals of all ages, enhancing overall user satisfaction. Whether it’s for bathroom usage or other plumbing needs, this model does not fall short in delivering top-tier performance.

Overall, the Sterling Plumbing 882.00253.00 stands out as a remarkable fixture that blends aesthetic appeal with cutting-edge technologies and user-focused design. Its durability, efficiency, and modern styling make it a favorable option for consumers looking to upgrade their plumbing solutions. Investing in this model means choosing a reliable product that aligns with both functionality and contemporary design principles.