Sterling Plumbing 882.00253.00 Name Description Options Default Special convey, No convey, Alarm

Page 38

Name

Description

Options

Default

Special convey

When this option is enabled, the station’s vacuum

disabled,

disabled

 

valve remains open for the convey time, even if

enabled

 

 

the station is not demanding material and is

 

 

 

indicating that it is full. When disabled, the

 

 

 

station’s vacuum valve opens when there is

 

 

 

demand from the station, and it remains open until

 

 

 

the convey time has elapsed or material trips the

 

 

 

volume-fill proximity switch.

 

 

 

Enable this option if and only if the station has no

 

 

 

flapper.

 

 

Name

Description

Options

Default

Alarm Options

 

 

 

No convey

When this option is enabled, the controller issues

disabled,

disabled

 

a “no convey” alarm if it has repeatedly attempted

enabled

 

 

to convey material to the station but the flapper

 

 

 

never opened during the dump delay. (The

 

 

 

number of attempts is controlled by the next

 

 

 

setting.)

 

 

 

Usually this option should be enabled. At times,

 

 

 

you may wish to disable it during operation as a

 

 

 

stopgap measure for dealing with an alarm.

 

 

# attempts before

Number of attempts before alarm: the number of

1–99

3

alarm

times the controller will attempt to convey material

 

 

 

to a station before it issues a “no convey” alarm.

 

 

 

The setting for this option depends on (a) how

 

 

 

much material your injection mold uses to make

 

 

 

each part compared with the capacity of the

 

 

 

receiver and (b) how important it is to keep your

 

 

 

injection mold from running out of material and

 

 

 

shutting down. A higher setting will give you fewer

 

 

 

alarms, at the risk of emptying the receiver without

 

 

 

warning. A lower setting will give more frequent

 

 

 

alarms, at the risk of disrupting operations

 

 

 

unnecessarily.

 

 

4 –Pump 38-Station Controllers

Chapter 6: Configurable Settings

37 of 44

Image 38
Contents SCC 4-Pump 38-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityOperator Responsibility Maintenance ResponsibilityReporting a Safety Defect General Description Functional DescriptionModels Covered in This Manual Electrical Features Standard FeaturesMechanical Features Controller FeaturesSafety Circuit Standards Optional FeaturesSafety Devices and Interlocks Fail Safe OperationSafety Device Lock-Outs Uncrating InstallationMaking Control Panel Power Drop Wiring Connections Mounting the Control PanelConnecting the Control Panel to the Pump Package SetupConnecting the Control Panel to Vacuum Hoppers Setting the Number of Stations and the Number of Pumps Default Station Status Screen Before SetupSetting Up Alarm Silences System Setup ScreenSetting Up Pump Staging Setting Up StationsStation Operator Screen Before Setup Setting Up Pumps Pump Status ScreenFinishing Setup Setting Up Passwords Setup PasswordOperator Password Initial Startup Basic Tasks OperationOverview Reviewing Station StatusColor Label Description Reviewing Pump Status Pump Status Screen During OperationPassword Entry Screen Logging On and Logging OffEnabling and Disabling Stations and Pumps Starting and Stopping the SystemReviewing and Adjusting Basic Station Settings Station Operator ScreenAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Navigating among the Station Operator ScreensAdjusting Advanced Settings Reviewing and Resetting a Pump Hour MeterTransferring Stations to a Standby Pump Transfer To Standby Pump ScreenTransfer To Standby Pump Button Silencing Alarms AlarmsReviewing Alarms Maintenance Configurable Settings Options for Station SetupNo convey Name Description Options Default Special conveyAlarm # attempts beforeOptions for Pump Setup Idle Time OptionsProblem Possible Cause Solution TroubleshootingGeneral Troubleshooting System Alarms Station AlarmsPump Alarms Alarm message Possible causeOptional Components WarrantyAppendix Quantity Part Number Description Drawings and DiagramsSpare Parts List Controller Safety Tags Safety Tag InformationWarranty Returns Returned Material PolicyController Identification Serial Number Tag Technical Assistance Contact Information

882.00253.00 specifications

Sterling Plumbing has established a solid reputation in the plumbing industry, and their model 882.00253.00 is an exemplary product that showcases quality and innovation. This particular item is part of Sterling's commitment to providing reliable and stylish plumbing fixtures that meet the needs of modern homes.

One of the standout features of the Sterling Plumbing 882.00253.00 is its exceptional design. The product is crafted with sleek lines and a contemporary aesthetic, making it an ideal choice for various bathroom styles, from minimalistic to more traditional setups. The finish is not only visually appealing but also practical, as it resists tarnishing and corrosion, ensuring durability and longevity.

In addition to its attractive design, the 882.00253.00 includes advanced technologies that enhance its functionality. The model employs a user-friendly installation system, allowing for a smooth and hassle-free setup. Homeowners or contractors can easily install this fixture without the need for specialized tools, reducing labor costs and installation time.

Another key characteristic of this plumbing fixture is its water efficiency. The Sterling 882.00253.00 is engineered with advanced flow technologies that help conserve water without compromising performance. This eco-friendly feature is becoming increasingly important as more consumers look for ways to reduce their environmental footprint and lower utility bills.

The Sterling Plumbing model also boasts robust construction. Made from high-quality materials, it is designed to withstand everyday wear and tear in busy households. The sturdy components ensure a dependable performance throughout its lifespan, making it a wise investment for homeowners and builders alike.

Furthermore, the 882.00253.00 emphasizes user comfort and accessibility. The ergonomic design and intuitive controls make it easy to use for individuals of all ages, enhancing overall user satisfaction. Whether it’s for bathroom usage or other plumbing needs, this model does not fall short in delivering top-tier performance.

Overall, the Sterling Plumbing 882.00253.00 stands out as a remarkable fixture that blends aesthetic appeal with cutting-edge technologies and user-focused design. Its durability, efficiency, and modern styling make it a favorable option for consumers looking to upgrade their plumbing solutions. Investing in this model means choosing a reliable product that aligns with both functionality and contemporary design principles.