Sterling Plumbing 882.00253.00 specifications Transfer To Standby Pump Button

Page 34

Figure 15: Transfer To Standby Pump Button

Note: When you enter the second pump number, the controller checks to make sure that both pumps are offline and that the standby pump has no stations assigned to it. If these conditions are not all met, error messages appear on the screen instead of MOVE button. If you get an error message, first check to make sure that you have entered the correct numbers and reenter if necessary. If another error occurs, see the Standby Pump Errors section on page 33.

7.Touch the MOVE button. When transfer is complete, stations moved will appear on the screen.

8.Touch RETURN, to return to the “Pump Setup” screen.

9.Put the standby pump online by briefly touching its icon. The icon changes color to show the new status, and the system begins using the pump. In addition, all “Station Operator” and “Station Setup” screens show the new pump assignment.

Standby Pump Errors

If the error message tells you to disable the source pump and/or the standby pump, touch RETURN at this screen, then PUMP STATUS at the “Pump Setup” screen. Take the pumps offline and then return to the “Transfer to Standby Pump” screen.

If the error message tells you that the standby pump has stations assigned, you must either use a different standby pump or you must remove the pump assignment for all stations assigned to the standby pump. To remove the assignments, complete the following steps:

1.Touch RETURN at the “Standby Pump” screen, and then touch STATION STATUS.

2.Touch and hold a station icon to get to the “Station Operator” screen.

3.Then touch STATION SETUP to go to the “Station Setup” screen.

4.Use PREVIOUS and NEXT to review all pump assignments.

5.Where necessary, choose ASSIGNED TO PUMP to set station assignments to 0 (unassigned). Then return to the “Transfer to Standby Pump” screen.

6.Touch left side pump value and enter the number of the pump whose hoppers are to be transferred.

7.Touch right side pump value and enter destination pump number.

4 –Pump 38-Station Controllers

Chapter 4: Operation

33 of 44

Image 34
Contents SCC 4-Pump 38-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings How to Use This Manual SafetySafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityReporting a Safety Defect Maintenance ResponsibilityOperator Responsibility Models Covered in This Manual Functional DescriptionGeneral Description Electrical Features Standard FeaturesMechanical Features Controller FeaturesSafety Circuit Standards Optional FeaturesSafety Devices and Interlocks Fail Safe OperationSafety Device Lock-Outs Uncrating InstallationMaking Control Panel Power Drop Wiring Connections Mounting the Control PanelConnecting the Control Panel to Vacuum Hoppers SetupConnecting the Control Panel to the Pump Package Setting the Number of Stations and the Number of Pumps Default Station Status Screen Before SetupSetting Up Alarm Silences System Setup ScreenSetting Up Pump Staging Setting Up StationsStation Operator Screen Before Setup Setting Up Pumps Pump Status ScreenFinishing Setup Setting Up Passwords Setup PasswordOperator Password Initial Startup Basic Tasks OperationOverview Reviewing Station StatusColor Label Description Reviewing Pump Status Pump Status Screen During OperationPassword Entry Screen Logging On and Logging OffEnabling and Disabling Stations and Pumps Starting and Stopping the SystemReviewing and Adjusting Basic Station Settings Station Operator ScreenAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Navigating among the Station Operator ScreensAdjusting Advanced Settings Reviewing and Resetting a Pump Hour MeterTransferring Stations to a Standby Pump Transfer To Standby Pump ScreenTransfer To Standby Pump Button Reviewing Alarms AlarmsSilencing Alarms Maintenance Configurable Settings Options for Station SetupNo convey Name Description Options Default Special conveyAlarm # attempts beforeOptions for Pump Setup Idle Time OptionsGeneral Troubleshooting TroubleshootingProblem Possible Cause Solution System Alarms Station AlarmsPump Alarms Alarm message Possible causeAppendix WarrantyOptional Components Spare Parts List Drawings and DiagramsQuantity Part Number Description Controller Safety Tags Safety Tag InformationWarranty Returns Returned Material PolicyController Identification Serial Number Tag Technical Assistance Contact Information

882.00253.00 specifications

Sterling Plumbing has established a solid reputation in the plumbing industry, and their model 882.00253.00 is an exemplary product that showcases quality and innovation. This particular item is part of Sterling's commitment to providing reliable and stylish plumbing fixtures that meet the needs of modern homes.

One of the standout features of the Sterling Plumbing 882.00253.00 is its exceptional design. The product is crafted with sleek lines and a contemporary aesthetic, making it an ideal choice for various bathroom styles, from minimalistic to more traditional setups. The finish is not only visually appealing but also practical, as it resists tarnishing and corrosion, ensuring durability and longevity.

In addition to its attractive design, the 882.00253.00 includes advanced technologies that enhance its functionality. The model employs a user-friendly installation system, allowing for a smooth and hassle-free setup. Homeowners or contractors can easily install this fixture without the need for specialized tools, reducing labor costs and installation time.

Another key characteristic of this plumbing fixture is its water efficiency. The Sterling 882.00253.00 is engineered with advanced flow technologies that help conserve water without compromising performance. This eco-friendly feature is becoming increasingly important as more consumers look for ways to reduce their environmental footprint and lower utility bills.

The Sterling Plumbing model also boasts robust construction. Made from high-quality materials, it is designed to withstand everyday wear and tear in busy households. The sturdy components ensure a dependable performance throughout its lifespan, making it a wise investment for homeowners and builders alike.

Furthermore, the 882.00253.00 emphasizes user comfort and accessibility. The ergonomic design and intuitive controls make it easy to use for individuals of all ages, enhancing overall user satisfaction. Whether it’s for bathroom usage or other plumbing needs, this model does not fall short in delivering top-tier performance.

Overall, the Sterling Plumbing 882.00253.00 stands out as a remarkable fixture that blends aesthetic appeal with cutting-edge technologies and user-focused design. Its durability, efficiency, and modern styling make it a favorable option for consumers looking to upgrade their plumbing solutions. Investing in this model means choosing a reliable product that aligns with both functionality and contemporary design principles.