Sterling Plumbing 882.00253.00 specifications Setting Up Pumps, Pump Status Screen

Page 20

5.As appropriate, setup the rest of the stations using either of the following methods:

Use the PREVIOUS or NEXT buttons to navigate to other stations. Touch PREVIOUS to go to the previous “Station Setup” screen, or touch NEXT to go to the next “Station Setup” screen.

Setting Up Pumps

Before starting the system, you must define several settings for each pump, such as how quickly to shut it down when it is not in use. This section first discusses how to use the controller’s menu system to configure pumps. The table on page 37 discusses the individual choices. In order to setup up the pumps properly, perform the following:

1.Go to the “Pump Status“ screen if needed. To reach this screen from any other screen, touch PUMP STATUS button. The “Pump Status” screen appears:

Figure 7: “Pump Status” Screen

2.Touch the icon for the pump you want to set up, and hold it for several seconds. The “Pump Setup” screen opens.

4 –Pump 38-Station Controllers

Chapter 3: Installation

19 of 44

Image 20
Contents SCC 4-Pump 38-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityOperator Responsibility Maintenance ResponsibilityReporting a Safety Defect General Description Functional DescriptionModels Covered in This Manual Standard Features Mechanical FeaturesElectrical Features Controller FeaturesOptional Features Safety Devices and InterlocksSafety Circuit Standards Fail Safe OperationSafety Device Lock-Outs Installation Making Control Panel Power Drop Wiring ConnectionsUncrating Mounting the Control PanelConnecting the Control Panel to the Pump Package SetupConnecting the Control Panel to Vacuum Hoppers Setting the Number of Stations and the Number of Pumps Default Station Status Screen Before SetupSetting Up Alarm Silences System Setup ScreenSetting Up Pump Staging Setting Up StationsStation Operator Screen Before Setup Setting Up Pumps Pump Status ScreenFinishing Setup Setting Up Passwords Setup PasswordOperator Password Initial Startup Operation OverviewBasic Tasks Reviewing Station StatusColor Label Description Reviewing Pump Status Pump Status Screen During OperationPassword Entry Screen Logging On and Logging OffEnabling and Disabling Stations and Pumps Starting and Stopping the SystemReviewing and Adjusting Basic Station Settings Station Operator ScreenAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Navigating among the Station Operator ScreensAdjusting Advanced Settings Reviewing and Resetting a Pump Hour MeterTransferring Stations to a Standby Pump Transfer To Standby Pump ScreenTransfer To Standby Pump Button Silencing Alarms AlarmsReviewing Alarms Maintenance Configurable Settings Options for Station SetupName Description Options Default Special convey AlarmNo convey # attempts beforeOptions for Pump Setup Idle Time OptionsProblem Possible Cause Solution TroubleshootingGeneral Troubleshooting Station Alarms Pump AlarmsSystem Alarms Alarm message Possible causeOptional Components WarrantyAppendix Quantity Part Number Description Drawings and DiagramsSpare Parts List Safety Tag Information Warranty ReturnsController Safety Tags Returned Material PolicyController Identification Serial Number Tag Technical Assistance Contact Information

882.00253.00 specifications

Sterling Plumbing has established a solid reputation in the plumbing industry, and their model 882.00253.00 is an exemplary product that showcases quality and innovation. This particular item is part of Sterling's commitment to providing reliable and stylish plumbing fixtures that meet the needs of modern homes.

One of the standout features of the Sterling Plumbing 882.00253.00 is its exceptional design. The product is crafted with sleek lines and a contemporary aesthetic, making it an ideal choice for various bathroom styles, from minimalistic to more traditional setups. The finish is not only visually appealing but also practical, as it resists tarnishing and corrosion, ensuring durability and longevity.

In addition to its attractive design, the 882.00253.00 includes advanced technologies that enhance its functionality. The model employs a user-friendly installation system, allowing for a smooth and hassle-free setup. Homeowners or contractors can easily install this fixture without the need for specialized tools, reducing labor costs and installation time.

Another key characteristic of this plumbing fixture is its water efficiency. The Sterling 882.00253.00 is engineered with advanced flow technologies that help conserve water without compromising performance. This eco-friendly feature is becoming increasingly important as more consumers look for ways to reduce their environmental footprint and lower utility bills.

The Sterling Plumbing model also boasts robust construction. Made from high-quality materials, it is designed to withstand everyday wear and tear in busy households. The sturdy components ensure a dependable performance throughout its lifespan, making it a wise investment for homeowners and builders alike.

Furthermore, the 882.00253.00 emphasizes user comfort and accessibility. The ergonomic design and intuitive controls make it easy to use for individuals of all ages, enhancing overall user satisfaction. Whether it’s for bathroom usage or other plumbing needs, this model does not fall short in delivering top-tier performance.

Overall, the Sterling Plumbing 882.00253.00 stands out as a remarkable fixture that blends aesthetic appeal with cutting-edge technologies and user-focused design. Its durability, efficiency, and modern styling make it a favorable option for consumers looking to upgrade their plumbing solutions. Investing in this model means choosing a reliable product that aligns with both functionality and contemporary design principles.