Sterling Plumbing 882.00253.00 specifications Setting Up Pump Staging, Setting Up Stations

Page 18

Setting Up Pump Staging

To avoid an excessive power demand at your facility when the conveying system starts up, you can stagger the times at which pumps start. Whenever a demand would cause two pumps to start simultaneously, your choice for pump staging sets the delay between the start of one pump and the start of the next. The factory default is a delay of three seconds. You need to change this setting only if this delay is too long or too short for your facility.

To set the delay between the start of one pump and the next, complete the following steps:

1.Go to the “System Setup” screen by touching the SYSTEM SETUP button on any screen.

2.Touch the PUMP STAGING button. A keypad pops up.

3.Enter the number of seconds (between 0 and 99) for the length of the delay between the start of one pump and the next. Use CLR to erase any mistakes. Use ENT to enter the value. The keypad disappears, and the new setting appears under PUMP STAGING.

Setting Up Stations

Before starting the system, you must define several settings for each station, such as which pump conveys material to it. This section first discusses how to use the controller’s menu system to configure stations. The table on pages 36–37 discusses the individual choices. To set up each station, perform the following:

1.Go to the “Station Status” screen if needed. To reach this screen press station status button on any screen.

Figure 4: “Station Status” Screen

2.On the “Station Status” screen (Figure 4), touch the icon for the station you want to setup, and hold it for several seconds. The “Station Operator” screen opens.

4 –Pump 38-Station Controllers

Chapter 3: Installation

17 of 44

Image 18
Contents SCC 4-Pump 38-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Safety How to Use This ManualSafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityMaintenance Responsibility Reporting a Safety DefectOperator Responsibility Functional Description Models Covered in This ManualGeneral Description Electrical Features Standard FeaturesMechanical Features Controller FeaturesSafety Circuit Standards Optional FeaturesSafety Devices and Interlocks Fail Safe OperationSafety Device Lock-Outs Uncrating InstallationMaking Control Panel Power Drop Wiring Connections Mounting the Control PanelSetup Connecting the Control Panel to Vacuum HoppersConnecting the Control Panel to the Pump Package Setting the Number of Stations and the Number of Pumps Default Station Status Screen Before SetupSetting Up Alarm Silences System Setup ScreenSetting Up Pump Staging Setting Up StationsStation Operator Screen Before Setup Setting Up Pumps Pump Status ScreenFinishing Setup Setting Up Passwords Setup PasswordOperator Password Initial Startup Basic Tasks OperationOverview Reviewing Station StatusColor Label Description Reviewing Pump Status Pump Status Screen During OperationPassword Entry Screen Logging On and Logging OffEnabling and Disabling Stations and Pumps Starting and Stopping the SystemReviewing and Adjusting Basic Station Settings Station Operator ScreenAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Navigating among the Station Operator ScreensAdjusting Advanced Settings Reviewing and Resetting a Pump Hour MeterTransferring Stations to a Standby Pump Transfer To Standby Pump ScreenTransfer To Standby Pump Button Alarms Reviewing AlarmsSilencing Alarms Maintenance Configurable Settings Options for Station SetupNo convey Name Description Options Default Special conveyAlarm # attempts beforeOptions for Pump Setup Idle Time OptionsTroubleshooting General TroubleshootingProblem Possible Cause Solution System Alarms Station AlarmsPump Alarms Alarm message Possible causeWarranty AppendixOptional Components Drawings and Diagrams Spare Parts ListQuantity Part Number Description Controller Safety Tags Safety Tag InformationWarranty Returns Returned Material PolicyController Identification Serial Number Tag Technical Assistance Contact Information

882.00253.00 specifications

Sterling Plumbing has established a solid reputation in the plumbing industry, and their model 882.00253.00 is an exemplary product that showcases quality and innovation. This particular item is part of Sterling's commitment to providing reliable and stylish plumbing fixtures that meet the needs of modern homes.

One of the standout features of the Sterling Plumbing 882.00253.00 is its exceptional design. The product is crafted with sleek lines and a contemporary aesthetic, making it an ideal choice for various bathroom styles, from minimalistic to more traditional setups. The finish is not only visually appealing but also practical, as it resists tarnishing and corrosion, ensuring durability and longevity.

In addition to its attractive design, the 882.00253.00 includes advanced technologies that enhance its functionality. The model employs a user-friendly installation system, allowing for a smooth and hassle-free setup. Homeowners or contractors can easily install this fixture without the need for specialized tools, reducing labor costs and installation time.

Another key characteristic of this plumbing fixture is its water efficiency. The Sterling 882.00253.00 is engineered with advanced flow technologies that help conserve water without compromising performance. This eco-friendly feature is becoming increasingly important as more consumers look for ways to reduce their environmental footprint and lower utility bills.

The Sterling Plumbing model also boasts robust construction. Made from high-quality materials, it is designed to withstand everyday wear and tear in busy households. The sturdy components ensure a dependable performance throughout its lifespan, making it a wise investment for homeowners and builders alike.

Furthermore, the 882.00253.00 emphasizes user comfort and accessibility. The ergonomic design and intuitive controls make it easy to use for individuals of all ages, enhancing overall user satisfaction. Whether it’s for bathroom usage or other plumbing needs, this model does not fall short in delivering top-tier performance.

Overall, the Sterling Plumbing 882.00253.00 stands out as a remarkable fixture that blends aesthetic appeal with cutting-edge technologies and user-focused design. Its durability, efficiency, and modern styling make it a favorable option for consumers looking to upgrade their plumbing solutions. Investing in this model means choosing a reliable product that aligns with both functionality and contemporary design principles.