FCC Notification

This device complies with part 15 of the FCC rules. Operation is subject to the following conditions:

1)This device may not cause harmful interference and

2)This device must accept any interference received, including interference that may cause undesired operation.

The device must be operated as supplied by Data-Linc Group. Any changes or modifications made to the device without the express written approval of Data-Linc Group may void the user’s authority to operate the device.

Caution: This device has a maximum transmitted output power of 955 mW. It is required that the transmit antenna be kept at least 23 cm away from nearby persons to satisfy FCC RF exposure requirements.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a industrial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

ƒReorient or relocate the receiving antenna.

ƒIncrease the separation between the equipment and receiver.

ƒConnect the equipment into an outlet on a circuit different from that to which the receiver is connected.

ƒConsult the dealer or an experienced radio/TV technician for help.

Note: Whenever any Data-Linc Group SRM series modem is placed inside an enclosure a label must be placed on the outside of that enclosure which includes the modem’s FCC ID.

The following antennas are approved for use with Data-Linc Group’s 900MHz series modems.

NOTE: Per FCC Rules, the maximum power allowed at the antenna is 4 Watts E.I.R.P.

900MHz Directional Antenna

 

Gain

Manufacturer

Manufacture Model Number

 

Data-Linc Model Number

 

 

8.2 dBi

Larsen

YA6900W

 

A-YB

 

 

11 dBi

Larsen

YA5900W

 

A-YHB

 

900MHz Omni-Directional Antenna

 

 

 

 

 

Gain

Manufacturer

Manufacture Model Number

Data-Linc Model Number

 

5.2 dBi

Maxrad

MAX9053

A-OB

 

7.2 dBi

Maxrad

MAX9075

A-O5B

 

0 dBi

Ying Hao

YH920801/AD-725-A-1

A-06/ADJ

 

0 dBi

Centurion

EXC-902-BN

A-06BH-3S / 10S (**)

(**) This part number refers to an antenna kit(s). The 0 dBi refers to the antenna portion of the kit.

Note: The antenna used for this device must be professionally installed on a fixed-mounted permanent outdoor structure for satisfying RF exposure requirements, including antenna co-location requirements of 1.1307(b)(3).

DATA-LINC GROUP

PN 161-09981-002C

Image 2
Contents DDAA1000/SRM FCC Notification Product User GuideTable of Contents DATA-LINC Group Introduction DDAA1000 and DD1000Teminal Block Power ConnectorAntenna Connectoin Type Discrete Operation ConnectionsPoint-to-Point Discrete Operation Master RemotePoint-to-Multipoint Discrete Operation MasterPoint-to-Point Analog System Supply loop powerAnalog Operation Needed. The DDAA1000 unites do notConnection of a flow meter to the DDAA1000/SRM unit Master or RemoteFactory Configuration Process Point-to-Multipoint Analog SystemPoint-to-Multipoint Analog Operation Point-to-Multipoint Analog Example RemoteChanging System or Radio Configurations Layout DrawingTechnical Specifications Troubleshooting Technical Support Product WarrantyReturn Material Authorization Contact InformationAppendix a TOPDDAA1000 DD1000 Configuration Appendix BDATA-LINC Group Ddaa Eeprom MENU** *SET Caplck DATA-LINC Group Appendix C Radio Configuration Terminal SettingsMain Menu Point-to-Point Remote Main Menu Option 0 Set Operation ModePoint-to-point Master Point-to-Multi-Point MasterPoint-to-Point Repeater Point-to-Point Remote/Master SwitchableDDAA1000/SRM User Guide Point-to-Point Remote/Repeater Point-to-Multi-Point RepeaterModBus RTU Main Menu Option 1 Set Baud RateAvailable data word length and parity selections Main Menu Option 2 Edit Call Book Call Book MenuEdit Call Book in Multi-Point Systems Entry Number Repeater 000-0000Max Packet Size and 2 Min Packet Size Selections Main Menu Option 3 Edit Radio Transmission CharacteristicsFreqKey DDAA1000/SRM User Guide Minimum Packet Size Settings bytes Maximum Packet Size Settings where RF Data Rate=3Xmit Rate RF Data RateRemote Security DDAA1000/SRM User Guide RF Xmit PowerPower Transmit Settings RTS to CTSMCU speed DDAA1000/SRM User Guide Lowpower ModeHigh Noise Average Noise Level Average Signal LevelMain Menu Option 4 Show Radio Statistics Overall Rcv Rate %Multi-Point Operation Radio TemperatureDDAA1000/SRM User Guide Number of Disconnects Main Menu Option 5 Edit Multi-Point Parameters Multi-Point ParametersSubNet ID DiagnosticsRemote/Repeater Radio IDMain Menu Option 8 Password Changing a Password Disabling PasswordDDAA1000/SRM and DD1000/SRM Placement Locations