Omron DDAA1000/SRM manual Remote/Repeater, Diagnostics, SubNet ID, Radio ID

Page 38

DDAA1000/SRM User Guide

Another parameter in a multi-point network is (4) DTR Connect. When set at (1), the remote will connect to the master if it is free when the DTR line goes high on the 9-pin RS232 connector. In setting (2), the radio modem will accumulate data in its buffer and transmit in a burst when the buffer is full. This mode is valuable when a network has many low data rate devices and it is desirable to increase overall network capacity. In setting (0), the radio modem will transmit when RS232 data is received.

The repeater’s hopping pattern must also be set in a multi-point network; this is accomplished with parameter (5) Repeater Frequency. Setting this parameter is in contrast with point-to-point mode where the repeater automatically uses the master’s hopping pattern. The repeater may be programmed to either use the master’s hopping pattern selection (0) or its own selection (1).

Option (6) NetWork ID allows multi-point networks to be established without the use of the Call Book. If the NetWork ID is set to any value lower than the default (255), the remotes in the multi-point network will communicate with the first multi- point master or repeater heard with the same NetWork ID. When the NetWork ID is used, multi-point masters and repeaters may be replaced without reprogramming all of the remotes in the network. In addition, this allows a remote to establish communications with different masters (though not at the same time) without having the call book numbers in the Call Book. This is very useful in mobile multi-point applications. (8) MultiMaster Synch is reserved for multi-point applications with concentrations of master units where it is necessary to reduce interference between the masters. Please contact the factory for more information on the use of this feature. The (9) 1PPS Enable/Delay This setting should not be changed from its default of 255. Contact the factory for further information.

(A) Remote/Repeater

The remote/repeater mode allows a DDAA1000/DD1000 in a multi-point system to simultaneously act as a remote and a repeater. When in this mode, a radio will repeat transmit any packets sent from a master as well as send them out the RS232 port. This allows a DDAA/DD1000 set as a slave/repeater to act as a remote at the same time. 0 disables this mode, 1 enables it.

(B) Diagnostics

The DDAA1000/DD1000 has no connection point for diagnostics.

(C) SubNet ID

The default setting is “Disabled.” Please see the SubNet ID section of this manual.

(D) Radio ID

Not used for DDAA1000/DD1000.

36

DATA-LINC GROUP

PN 161-09981-002C

rev 8/04

Image 38
Contents DDAA1000/SRM FCC Notification Product User GuideTable of Contents DATA-LINC Group Introduction DDAA1000 and DD1000Teminal Block Power ConnectorAntenna Connectoin Type Discrete Operation ConnectionsPoint-to-Point Discrete Operation Master RemotePoint-to-Multipoint Discrete Operation MasterPoint-to-Point Analog System Supply loop powerAnalog Operation Needed. The DDAA1000 unites do notConnection of a flow meter to the DDAA1000/SRM unit Master or RemoteFactory Configuration Process Point-to-Multipoint Analog SystemPoint-to-Multipoint Analog Operation Point-to-Multipoint Analog Example RemoteChanging System or Radio Configurations Layout DrawingTechnical Specifications Troubleshooting Technical Support Product WarrantyReturn Material Authorization Contact InformationAppendix a TOPDDAA1000 DD1000 Configuration Appendix BDATA-LINC Group Ddaa Eeprom MENU** *SET Caplck DATA-LINC Group Appendix C Radio Configuration Terminal SettingsMain Menu Point-to-Point Remote Main Menu Option 0 Set Operation ModePoint-to-point Master Point-to-Multi-Point MasterPoint-to-Point Repeater Point-to-Point Remote/Master SwitchableDDAA1000/SRM User Guide Point-to-Point Remote/Repeater Point-to-Multi-Point RepeaterModBus RTU Main Menu Option 1 Set Baud RateAvailable data word length and parity selections Main Menu Option 2 Edit Call Book Call Book MenuEdit Call Book in Multi-Point Systems Entry Number Repeater 000-0000Max Packet Size and 2 Min Packet Size Selections Main Menu Option 3 Edit Radio Transmission CharacteristicsFreqKey DDAA1000/SRM User Guide Minimum Packet Size Settings bytes Maximum Packet Size Settings where RF Data Rate=3Xmit Rate RF Data RateRemote Security DDAA1000/SRM User Guide RF Xmit PowerPower Transmit Settings RTS to CTSMCU speed DDAA1000/SRM User Guide Lowpower ModeHigh Noise Average Noise Level Average Signal LevelMain Menu Option 4 Show Radio Statistics Overall Rcv Rate %Multi-Point Operation Radio TemperatureDDAA1000/SRM User Guide Number of Disconnects Main Menu Option 5 Edit Multi-Point Parameters Multi-Point ParametersSubNet ID DiagnosticsRemote/Repeater Radio IDMain Menu Option 8 Password Changing a Password Disabling PasswordDDAA1000/SRM and DD1000/SRM Placement Locations