Omron manual DDAA1000/SRM User Guide Minimum Packet Size Settings bytes

Page 31

DDAA1000/SRM User Guide

Table 4: Minimum Packet Size Settings (bytes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

 

Min Packet Size

 

Setting

Min Packet Size

 

 

 

 

 

RF Data Rate = 2

 

RF Data Rate = 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

16

 

 

 

 

0

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

21

 

 

 

 

1

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

26

 

 

 

 

2

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

32

 

 

 

 

3

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

37

 

 

 

 

4

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

42

 

 

 

 

5

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

48

 

 

 

 

6

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

53

 

 

 

 

7

 

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

58

 

 

 

 

8

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

64

 

 

 

 

9

 

44

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5: Maximum Packet Size Settings where RF Data Rate=3

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

1

2

 

3

 

4

5

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

8

 

 

24

40

 

56

 

72

88

104

120

136

152

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

28

44

 

60

 

76

92

108

124

140

156

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

16

 

32

48

 

64

 

80

96

112

128

144

160

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

36

52

 

68

 

84

100

116

132

148

164

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

24

 

40

56

 

72

 

88

104

120

136

152

168

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

44

60

 

76

 

92

108

124

140

156

172

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

 

48

64

 

80

 

96

112

128

144

160

176

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

 

52

68

 

84

 

100

116

132

148

164

180

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

56

72

 

88

 

104

140

136

152

168

184

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

 

60

76

 

92

 

108

124

140

156

172

188

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN 161-09981-002C

rev 8/04

DATA-LINC GROUP

29

Image 31
Contents DDAA1000/SRM Product User Guide FCC NotificationTable of Contents DATA-LINC Group DDAA1000 and DD1000 IntroductionAntenna Connectoin Type Power ConnectorTeminal Block Connections Discrete OperationMaster Remote Point-to-Point Discrete OperationMaster Point-to-Multipoint Discrete OperationNeeded. The DDAA1000 unites do not Supply loop powerAnalog Operation Point-to-Point Analog SystemMaster or Remote Connection of a flow meter to the DDAA1000/SRM unitPoint-to-Multipoint Analog System Factory Configuration ProcessPoint-to-Multipoint Analog Example Remote Point-to-Multipoint Analog OperationLayout Drawing Changing System or Radio ConfigurationsTechnical Specifications Troubleshooting Contact Information Product WarrantyReturn Material Authorization Technical SupportTOP Appendix aAppendix B DDAA1000 DD1000 ConfigurationDATA-LINC Group Ddaa Eeprom MENU** *SET Caplck DATA-LINC Group Terminal Settings Appendix C Radio ConfigurationMain Menu Point-to-Multi-Point Master Main Menu Option 0 Set Operation ModePoint-to-point Master Point-to-Point RemotePoint-to-Multi-Point Repeater Point-to-Point Remote/Master SwitchableDDAA1000/SRM User Guide Point-to-Point Remote/Repeater Point-to-Point RepeaterAvailable data word length and parity selections Main Menu Option 1 Set Baud RateModBus RTU Call Book Menu Main Menu Option 2 Edit Call BookEntry Number Repeater 000-0000 Edit Call Book in Multi-Point SystemsFreqKey Main Menu Option 3 Edit Radio Transmission CharacteristicsMax Packet Size and 2 Min Packet Size Selections Maximum Packet Size Settings where RF Data Rate=3 DDAA1000/SRM User Guide Minimum Packet Size Settings bytesRF Data Rate Xmit RateRTS to CTS DDAA1000/SRM User Guide RF Xmit PowerPower Transmit Settings Remote SecurityHigh Noise DDAA1000/SRM User Guide Lowpower ModeMCU speed Overall Rcv Rate % Average Signal LevelMain Menu Option 4 Show Radio Statistics Average Noise LevelDDAA1000/SRM User Guide Number of Disconnects Radio TemperatureMulti-Point Operation Multi-Point Parameters Main Menu Option 5 Edit Multi-Point ParametersRadio ID DiagnosticsRemote/Repeater SubNet IDMain Menu Option 8 Password Disabling Password Changing a PasswordDDAA1000/SRM and DD1000/SRM Placement Locations