Omron DDAA1000/SRM manual Edit Call Book in Multi-Point Systems, Entry Number Repeater 000-0000

Page 29

DDAA1000/SRM User Guide

Entering or Modifying Numbers in the Call Book

Entering or modifying call book numbers in the Call Book is a straightforward process. When in the Call Book menu, select the entry number (0 – 9) you wish to edit. You will be prompted for the new number (formatting is automatic, you do not need to enter the dash). Once the number is entered (unless it is 000-0000) you will be asked for the call number of the first repeater to be used. If no repeater is to be used, enter the escape key; your entry will be complete and you will be back in the Call Book menu screen. If you enter a repeater number, you will then be prompted for the call number of the second repeater to use. If a second repeater is being used, enter the call number at this time; if not, enter the escape key. Once again, the radio modem will retain your entries, as shown in the updated Call Book menu screen.

Note: It is important that the Call Book slots (0 – 9) are filled sequentially beginning with 0, the first slot in the book. Call Book numbers do not need to be entered in numerical order; however, there must not be any 000-0000 numbers in the middle of the list of good Call Book numbers. The reason for this is that when a master is instructed to Call All available remotes, it will call all remotes listed until it reaches the first number of 000-0000. If a valid call book number is entered after the all zero number, it will not be recognized as a valid number to be called by the master.

Edit Call Book in Multi-Point Systems

In a multi-point system, the remotes and repeaters are not listed in the master’s Call Book. When establishing such a system, it is necessary only to have the master’s Call Book number in each remote’s and repeater’s Call Book, and to have each repeater’s Call Book number in the Call Book of each remote which may potentially communicate through it.

The following example shows the Call Books of a multi-point system comprised of a master, repeater and remote in which the remote can communicate either through the repeater or directly to the master:

Multi-Point Master Call Book (Unit Call Book number 555-0001)

Entry

Number

Repeater 1

Repeater 2

 

 

 

 

(0)

000-0000

 

 

 

 

 

 

(1)

000-0000

 

 

 

 

 

 

No call book number entries are necessary in the master’s Call Book

The master’s Call Book may be programmed to call any entry

Multi-Point Repeater Call Book (Unit Call Book number 555-0002)

Entry

Number

Repeater 1

Repeater 2

 

 

 

 

(0)

555-0001

 

 

 

 

 

 

(1)

000-0000

 

 

 

 

 

 

Multi-Point Remote Call Book (Unit Call Book number 555-0003)

Entry

Number

Repeater 1

Repeater 2

 

 

 

 

(0)

555-0001

 

 

 

 

 

 

(1)

555-0002

 

 

 

 

 

 

(2)

000-0000

 

 

 

 

 

 

PN 161-09981-002C

rev 8/04

DATA-LINC GROUP

27

Image 29
Contents DDAA1000/SRM Product User Guide FCC NotificationTable of Contents DATA-LINC Group DDAA1000 and DD1000 IntroductionTeminal Block Power ConnectorAntenna Connectoin Type Connections Discrete OperationMaster Remote Point-to-Point Discrete OperationMaster Point-to-Multipoint Discrete OperationAnalog Operation Supply loop powerPoint-to-Point Analog System Needed. The DDAA1000 unites do notMaster or Remote Connection of a flow meter to the DDAA1000/SRM unitPoint-to-Multipoint Analog System Factory Configuration ProcessPoint-to-Multipoint Analog Example Remote Point-to-Multipoint Analog OperationLayout Drawing Changing System or Radio ConfigurationsTechnical Specifications Troubleshooting Return Material Authorization Product WarrantyTechnical Support Contact InformationTOP Appendix aAppendix B DDAA1000 DD1000 ConfigurationDATA-LINC Group Ddaa Eeprom MENU** *SET Caplck DATA-LINC Group Terminal Settings Appendix C Radio ConfigurationMain Menu Point-to-point Master Main Menu Option 0 Set Operation ModePoint-to-Point Remote Point-to-Multi-Point MasterDDAA1000/SRM User Guide Point-to-Point Remote/Repeater Point-to-Point Remote/Master SwitchablePoint-to-Point Repeater Point-to-Multi-Point RepeaterModBus RTU Main Menu Option 1 Set Baud RateAvailable data word length and parity selections Call Book Menu Main Menu Option 2 Edit Call BookEntry Number Repeater 000-0000 Edit Call Book in Multi-Point SystemsMax Packet Size and 2 Min Packet Size Selections Main Menu Option 3 Edit Radio Transmission CharacteristicsFreqKey Maximum Packet Size Settings where RF Data Rate=3 DDAA1000/SRM User Guide Minimum Packet Size Settings bytesRF Data Rate Xmit RatePower Transmit Settings DDAA1000/SRM User Guide RF Xmit PowerRemote Security RTS to CTSMCU speed DDAA1000/SRM User Guide Lowpower ModeHigh Noise Main Menu Option 4 Show Radio Statistics Average Signal LevelAverage Noise Level Overall Rcv Rate %Multi-Point Operation Radio TemperatureDDAA1000/SRM User Guide Number of Disconnects Multi-Point Parameters Main Menu Option 5 Edit Multi-Point ParametersRemote/Repeater DiagnosticsSubNet ID Radio IDMain Menu Option 8 Password Disabling Password Changing a PasswordDDAA1000/SRM and DD1000/SRM Placement Locations