Installation

9. Push the stove straight

 

 

back, leaving a minimum

 

 

of 100mm (4”) clearance

 

 

from the back of the

 

 

stove to the wall. Seal the

 

 

vent pipe to the thimble

 

Exhaust

with

high

temperature

 

 

 

silicone.

 

 

 

80mm (3") or 100mm (4")

10. The pipe must extend at

 

Vent Pipe

 

Wall Thimble

least 30 cm (12”) away

 

from

the

building.

If

 

45o Elbow with Screen

necessary, bring another

Fresh Air Intake

length of pipe to the

or Termination Cap

 

 

outside of

the home

 

 

to connect

to the

first

 

High Temperature RTV

section. Do not forget to

 

 

Silicone Required

place

high

temperature

Figure 9: Straight through wall Installation.

silicone around the pipe

that passes through the thimble.

11.Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent terminates several feet above ground level and there are no trees, plants, etc. within several feet, a 45° elbow can be used as termination. The elbow must be turned down to prevent rain from entering.

NOTE:

Some horizontal through wall installations may require a “T” and 91 to 152 cm (3 to 5 feet) of vertical pipe outside the building to help naturally draft in the unit.

This may be required if a proper burn cannot be maintained, after the stove has been tested and the airflow set.

This is due to the back pressure in the exhaust caused by airflow around the structure.

All sections of pipe must have three (3) screws evenly spaced and all horizontal and vertical vent sections located within the house must have a bead of high temperature silicone installed on the male end of the pipe before installation to create a gas tight seal.

Wall framing

Horizontal frame for thimble

Vent pipe

Termination cap

Wall thimble

������ �������

Figure 10: Straight through Wall Installation - Side View.

12

Image 12
Contents Windsor Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Installation Rating label is located on the back of the hopperWindsor Dimensions Windsor Specifications Depth 815mm Area Under Sundeck Exhaust 100mm With High Through Wall with Horizontal Termination Finally, extend the pellet Outside Vertical Installation Hearth Mount Side View Exhaust Box, slide the pipe To Supply Power to the Exhaust Blower Exhaust Blower Installation Vertical Termination Thermostat wire placement Special Notes Troubleshooting Do notExhaust motor will not function normally 200 F 93 C high limit temperature sensor has tripped Wiring Diagram Parts List Components Reference Description Part Number50-1577 Parts List Cast Components DiagramSCastteelParts Installation Data Sheet Name of Owner Address