Installation
VERTICAL RISE WITH HORIZONTAL TERMINATION INSTALLATION (RECOMMENDED):
A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).
Termination cap |
|
90°elbow |
|
Wall framing |
|
Vertical section |
|
of vent pipe | Wall strap |
| |
Horizontal frame |
|
for thimble |
|
| Clean out tee |
| Wall thimble |
������ ������� |
|
Figure 11: Through Wall with Horizontal Termination.
THROUGH CONCRETE WALL WITH VERTICAL RISE INSTALLATIONS:
A 45° down elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).
Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove.
The termination must be 305mm (12”) from the outside wall and 305mm (12”) above the ground.
Horizontal frame |
|
for thimble | Termination |
Wall thimble | cap |
| |
90°elbow |
|
Wall framing |
|
Vertical section |
|
of vent pipe |
|
| Concrete |
| Wall |
������ ������� | Clean out tee |
Figure 12: Vertical rise with Horizontal Termination.
13