Enviro 50-1578 technical manual Outside Vertical Installation

Page 15

Installation

OUTSIDE VERTICAL INSTALLATIONS:

To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL INSTALLATIONS

-FREESTANDING” section and then finish it by performing the following (refer to Figure 14).

1.Install a tee with clean out on the outside of the house.

2.Install vent pipe upward from the tee. Make sure that you install support brackets to keep the vent straight and secure.

3.Install ceiling thimble and secure the flashing as you go through the roof.

4.Ensure that the rain cap is approximately 900 mm (36”) above the roof.

Rain cap

Flashing

900mm

(36")

75mm (3")

Clearance

100mm

(4")

Support

bracket

Tee with

cleanout

Type "L"

vent

Fresh air

intake

Figure 14: Outside Vertical Installation.

15

Image 15
Contents Windsor Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Rating label is located on the back of the hopper InstallationWindsor Dimensions Windsor Specifications Depth 815mm Area Under Sundeck Exhaust 100mm With High Through Wall with Horizontal Termination Finally, extend the pellet Outside Vertical Installation Hearth Mount Side View Exhaust Box, slide the pipe To Supply Power to the Exhaust Blower Exhaust Blower Installation Vertical Termination Thermostat wire placement Special Notes Do not TroubleshootingExhaust motor will not function normally 200 F 93 C high limit temperature sensor has tripped Wiring Diagram Reference Description Part Number Parts List Components50-1577 Parts List Cast Components DiagramSCastteelParts Name of Owner Address Installation Data Sheet