Installation | |
DIMENSIONS & SPECIFICATIONS: |
|
141/4" |
|
(360mm) |
|
| 153/8" |
| (390mm) |
253/4" | 257/8" |
(653mm) | (659mm) |
| 271/8" |
| (689mm) |
241/8" |
|
(614mm) |
|
Figure 2: Windsor Dimensions.
Table 1: Windsor Specifications.
Classification | Testing Standard | Description | ||
|
|
|
|
|
Class I | EN14785:2006 | Residential Wood Pellet Heater | ||
|
|
|
|
|
|
|
|
|
|
Voltage | Current | Frequency | ||
|
|
|
|
|
220 - 240 V | 2.0 - 2.3 Amps | 50 Hz | ||
|
|
|
|
|
|
|
|
|
|
Maximum Power Requirement | Fuel type | Calorific value of Pellet used | ||
|
|
|
|
|
525W (1793 BTU/hr) | wood pellets - 6mm (1⁄4”) dia. | ≥ 5.10 kWh/kg (≥ 8000 BTU/lb) | ||
|
|
|
|
|
|
|
|
|
|
Maximum Flue Gas Temperature | Mean Flue Gas Temperature | Mean Flue Gas Temperature (Reduced) | ||
|
|
|
|
|
230°C (446°F) | 180.5°C (357°F) | 128.5°C (263°F) | ||
|
|
|
|
|
|
|
|
|
|
Nominal Heat Output | CO emissions from Combustion | Energy Efficiency | ||
|
|
|
|
|
6.9 KWh (23544 BTU) | 0.035% |
|
| 82.6% |
|
|
|
|
|
|
|
|
|
|
Reduced Heat Output | CO emissions from Combustion (Reduced Output) | Energy Efficiency (Reduced Output) | ||
|
|
|
|
|
2.3 KWh (7848 BTU) | 0.052% |
|
| 77.3% |
|
|
|
|
|
|
|
|
|
|
CO2 at Nominal Output | Nominal Fuel Consumption Rate | Unit with Full Hopper | ||
8.16% | 1.65 Kg/hr (3.64 lb/hr)* | ~ 151kg (333lb) | ||
|
|
|
|
|
CO2 at Reduced Output | Fuel Consumption Rate (Reduced Output) | Hopper Capacity | ||
4.142% | 0.59 Kg/hr (1.30 lb/hr)* | ~ 20kg (45lb) |
*Note: Consumption will vary with the type of fuel used.
7