Enviro 50-1578 technical manual To Supply Power to the Exhaust Blower

Page 18

Installation

9.Connect the wires in the stove. Re-install the left side access cover to the stove and the back grill on the exterior vent housing.

10.Set the Slider Damper as described in the INSTALLATION - SLIDER/DAMPER SETTING“ section.

NOTE:

Ensure that all vent connections are installed by placing three (3) screws evenly spaced and a small bead of high temperature silicone at each chimney connection. Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles are maintained in accordance with the vent manufacturer’s specifications.

Vent termination cap

Siding

(stainless steel termination

hood) or 45° elbow with

rodent screen

Wall strap

(recommended with

use of vent pipe)

Vent pipe or 610mm (2 foot) riser

Pipe adapter (if using riser)

Exterior blower and housing

Horizontal frame for thimble

Armour cable supplying power to exterior blower

90° elbow

Wall framing

Wall thimble

Figure 19: Exhaust Blower Installation; Horizontal Termination.

TO SUPPLY POWER TO THE EXHAUST BLOWER:

Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar. Hook up to wires from the wiring harness for the exhaust blower. All electrical connections must be in accordance with local code requirements (see

WIRING DIAGRAM).

18

Image 18
Contents Windsor Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Installation Rating label is located on the back of the hopperWindsor Dimensions Windsor Specifications Depth 815mm Area Under Sundeck Exhaust 100mm With High Through Wall with Horizontal Termination Finally, extend the pellet Outside Vertical Installation Hearth Mount Side View Exhaust Box, slide the pipe To Supply Power to the Exhaust Blower Exhaust Blower Installation Vertical Termination Thermostat wire placement Special Notes Troubleshooting Do notExhaust motor will not function normally 200 F 93 C high limit temperature sensor has tripped Wiring Diagram Parts List Components Reference Description Part Number50-1577 Parts List Cast Components DiagramSCastteelParts Installation Data Sheet Name of Owner Address