Installation
CLEARANCES TO COMBUSTIBLES:
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for serving, routine cleaning and maintenance.
Side wall to unit | 200mm | (77⁄8 inches) |
Back wall to unit | 100mm | (4 inches) |
Corner to unit | 100mm | (4 inches) |
In Front of unit | 800mm | (311⁄2” inches) |
This pellet stove requires floor protection. The floor protection must be
Hearth Pad Size: |
| |
Width: | 650 mm | (25 5⁄8”) |
Depth: | 815mm | (32 1⁄8”) |
ALCOVE CLEARANCES:
|
| Back wall |
|
|
|
|
| 100mm | Adjacent |
|
| 100mm (4") | wall | |
|
|
| (4") |
|
wall | 200mm |
|
| |
(77/8 | inches) |
|
| |
Side |
|
| ||
|
|
|
| |
|
|
| 150mm |
|
|
|
| (6") |
|
|
| Floor Protection |
|
|
Figure 3: Minimum Clearances to Combustibles for
Freestanding Windsor.
This unit may be installed in an alcove. Maintain the clearances to combustibles shown in Figure 4.
Minimum Alcove width | 1220mm | (48 inches) |
Minimum Alcove height | 1220mm | (48 inches) |
Maximum Alcove depth | 915mm | (36 inches) |
Install vent at clearances specified by the vent manufacturer.
Minimum Width |
1220mm (48") |
Minimum Height |
1220mm (48") |
Maximum Depth |
915mm (36") |
Figure 4: Alcove Clearances.
8