Enviro 50-1578 technical manual Depth 815mm

Page 8

Installation

CLEARANCES TO COMBUSTIBLES:

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for serving, routine cleaning and maintenance.

Side wall to unit

200mm

(77⁄8 inches)

Back wall to unit

100mm

(4 inches)

Corner to unit

100mm

(4 inches)

In Front of unit

800mm

(311⁄2” inches)

This pellet stove requires floor protection. The floor protection must be non-combustible, extending beneath the stove the full width and depth of the unit including 150mm (6“) in front for ember protection.

Hearth Pad Size:

 

Width:

650 mm

(25 5⁄8”)

Depth:

815mm

(32 1⁄8”)

ALCOVE CLEARANCES:

 

 

Back wall

 

 

 

 

 

100mm

Adjacent

 

 

100mm (4")

wall

 

 

 

(4")

 

wall

200mm

 

 

(77/8

inches)

 

 

Side

 

 

 

 

 

 

 

 

 

150mm

 

 

 

 

(6")

 

 

 

Floor Protection

 

 

Figure 3: Minimum Clearances to Combustibles for

Freestanding Windsor.

This unit may be installed in an alcove. Maintain the clearances to combustibles shown in Figure 4.

Minimum Alcove width

1220mm

(48 inches)

Minimum Alcove height

1220mm

(48 inches)

Maximum Alcove depth

915mm

(36 inches)

Install vent at clearances specified by the vent manufacturer.

Minimum Width

1220mm (48")

Minimum Height

1220mm (48")

Maximum Depth

915mm (36")

Figure 4: Alcove Clearances.

8

Image 8
Contents Windsor Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Installation Rating label is located on the back of the hopperWindsor Dimensions Windsor Specifications Depth 815mm Area Under Sundeck Exhaust 100mm With High Through Wall with Horizontal Termination Finally, extend the pellet Outside Vertical Installation Hearth Mount Side View Exhaust Box, slide the pipe To Supply Power to the Exhaust Blower Exhaust Blower Installation Vertical Termination Thermostat wire placement Special Notes Troubleshooting Do notExhaust motor will not function normally 200 F 93 C high limit temperature sensor has tripped Wiring Diagram Parts List Components Reference Description Part Number50-1577 Parts List Cast Components DiagramSCastteelParts Installation Data Sheet Name of Owner Address