Safety Warnings & Recommendations

FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “Air Tight Homes” or where required by local codes.

Consider all large air moving devices when installing your unit and provide room air accordingly. NOTE: Extractor fans when operating in the same room or space as the appliance, may cause problems. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion.

The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash pan and viewing door must be locked securely for proper and safe operation of the pellet stove.

Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by adjusting the slider damper located on the left side of the stove.

Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn (black tipped, lazy orange flames).

If you have any questions with regards to your stove or the above-mentioned information, please feel free to contact your local dealer for further clarification and comments.

SINCE SHERWOOD INDUSTRIES LTD. HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, SHERWOOD INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

5

Image 5
Contents Windsor Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Rating label is located on the back of the hopper InstallationWindsor Dimensions Windsor Specifications Depth 815mm Area Under Sundeck Exhaust 100mm With High Through Wall with Horizontal Termination Finally, extend the pellet Outside Vertical Installation Hearth Mount Side View Exhaust Box, slide the pipe To Supply Power to the Exhaust Blower Exhaust Blower Installation Vertical Termination Thermostat wire placement Special Notes Do not TroubleshootingExhaust motor will not function normally 200 F 93 C high limit temperature sensor has tripped Wiring Diagram Reference Description Part Number Parts List Components50-1577 Parts List Cast Components DiagramSCastteelParts Name of Owner Address Installation Data Sheet