Harman Stove Company PC 45 #7 Installing through the ceiling vent, Minimumflue vent configuration

Page 12

Venting

12" min.

Storm collar

 

 

Flashing

3" min.

 

3" min.

3" min.

 

PL vent manufacturer's

fire stop s pa ce r an d

support

Fig. 18

No insulationor other combustible materials are allowed within 3" of the PL vent pipe.

(See Page 6 for corner installation clearances)

Minimumflue vent configuration

It is recommended that outside air be installed with this venting configuration.

1"2veaob roundg velle

#7 Installing through the ceiling vent

Through the ceiling vent, follow PL vent manufacturers recommendations when using wall and ceiling pass through.

Fig. 20

12 PC 45 Corn/Pellet Stove

inM.

Fig. 19

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER

WARNING

DO NOT INSTALL IN SLEEPING ROOM

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL,AND CEILING/ ROOF MUST BE MAINTAINED.

CAUTION

THE STOVE IS HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS.

Image 12
Contents Installation & Operating Manual Harman PC 45 Corn/Pellet StovePC 45 Corn/Pellet Stove Table of Contents IntroductionAssembly and Installation Installing rear cover panelsUnpacking FirebrickDoor Assembly/Installation Tips Assembling the doorInstallation InstallingMobile Home Installation With outside air installed With outside air installed, 6 feetVenting Vent Pipe Outside Air#1 Preferred method #2 Preferred method#3 Installing into an existing Chimney US only #4 Installing into an existing fireplace chimney US only#6 Installing into an existing chimney US and Canada #7 Installing through the ceiling vent Minimumflue vent configurationIgniter switch to Auto Stove Temperature ModeAutomatic IGNITION/OPERATION Automatic Start UP Starting the FireManual Stove Temperature Mode Igniter Switch to Manual Manual IGNITION/OPERATIONShut-Down Procedure Manual Start UPBurning Corn Burning PelletsStatus light error messages Automatic Ignition ESP ControlLow Draft Voltage Adjustment Low Draft Voltage AdjustmentMaintenance CleaningRemoving Ashes Cleaning of Feeder Fines Area Soot and Fly AshMaintenance Burn Pot Burn Pot Cleaning and MaintenanceCleaning of Burnpot Parts PC 45 Trouble-Shooting Cleaning Burn PotHelpful Hints FuelFeeder and Specifications SpecificationsCleaning Gold Door OptionsSunrise Gold Trim Gold Door Room Sensor Installation Hopper Extension OptionsSide Heat Shields Optional Pellet Burnpot GratePC 45 Wiring Diagram PC 45 Parts List Description Part NumberYear Limited Warranty Commercial