Harman Stove Company PC 45 manual Vent Pipe, Outside Air

Page 8

Venting

IMPORTANT NOTICE

Pellet Vent Pipe or PL Vent Pipe Must be used.

A combustion blower is used to extract the com- bustion gases from the firebox. This causes a nega- tive pressure in the firebox and a positive pressure in the venting system as shown in fig. 10. The longer the vent pipe and more elbows used in the system, the greater the flow resistance. Because of these facts we recommend using as few elbows as pos- sible and 15 feet or less of vent pipe. The maximum horizontal run should not exceed 48". If more than 15 feet of pipe is needed, the diameter should be increased from3" to 4" because a larger pipe causes less flow resistance. Be sure to use approved pellet vent pipe wall and ceiling pass through fittings to go through combustible walls and ceilings. Be sure to use a starting collar to attach the venting system to the stove. The starting col- lar must be sealed to the stove with high temp silicone caulking.

Vent Pipe

Fig. 10

Fig. 11

+ = Positive static pressure = Negative static pressure

Outside air flex pipe goes here

Flex pipe part# 2-00-08543

InletCover part# 1-10-08542

Pellet venting pipe ( also known as PL vent ) is constructed of two layers with air space between the layers. This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of only 3 inches. The sections of pipe lock together to form an air tight seal in most cases; however, in some cases a per- fect seal is not achieved. For this reason and the fact that the PC45 operates with a positive vent pres- sure we specify that the joints also be sealed with clear silicone.

Outside Air

Outside air is optional except in mobile homes and where building codes require. The benefit of outside air is mainly noticed in small very tight houses.

To install outside air use 2 3/8" I.D. flex pipe part number 2-00-08543. There is a break-away hole on the rear panel which must be removed before connecting the flex pipe. The pipe should be run out- side and terminate 3 feet or more to the side or be- low the vent pipe outlet. Never terminate the outside air above the vent pipe outlet. The maximum length run of this pipe is 15 feet. If a longer run is needed the size must be increased to 3". Inlet cover part number 1-10-08542 should be used to keep birds, rodents etc.out of pipe.

HRV

When installing in a house with a Heat Reclaim- ing Ventilation System (HRV) be sure the system is balanced and is not creating a negative pressure in

8 PC 45 Corn/Pellet Stove

the house.

Image 8
Contents Installation & Operating Manual Harman PC 45 Corn/Pellet StovePC 45 Corn/Pellet Stove Table of Contents IntroductionAssembly and Installation Installing rear cover panelsUnpacking FirebrickDoor Assembly/Installation Tips Assembling the doorMobile Home Installation InstallationInstalling Venting With outside air installedWith outside air installed, 6 feet Vent Pipe Outside Air#1 Preferred method #2 Preferred method#3 Installing into an existing Chimney US only #4 Installing into an existing fireplace chimney US only#6 Installing into an existing chimney US and Canada #7 Installing through the ceiling vent Minimumflue vent configurationAutomatic IGNITION/OPERATION Igniter switch to AutoStove Temperature Mode Automatic Start UP Starting the FireManual Stove Temperature Mode Igniter Switch to Manual Manual IGNITION/OPERATIONShut-Down Procedure Manual Start UPBurning Corn Burning PelletsStatus light error messages Automatic Ignition ESP ControlLow Draft Voltage Adjustment Low Draft Voltage AdjustmentRemoving Ashes MaintenanceCleaning Cleaning of Feeder Fines Area Soot and Fly AshCleaning of Burnpot Parts Maintenance Burn PotBurn Pot Cleaning and Maintenance PC 45 Trouble-Shooting Cleaning Burn PotHelpful Hints FuelFeeder and Specifications SpecificationsSunrise Gold Trim Gold Door Cleaning GoldDoor Options Room Sensor Installation Hopper Extension OptionsSide Heat Shields Optional Pellet Burnpot GratePC 45 Wiring Diagram PC 45 Parts List Description Part NumberYear Limited Warranty Commercial