Harman Stove Company PC 45 manual #1 Preferred method, #2 Preferred method

Page 9

Venting

3 ft.

Fig. 12

to

combustibles

 

3 ft.

 

to

Fig. 13

combustibles

 

#1 Preferred method

This method provides excellent venting for nor- mal operation and allows the stove to be installed closest to the wall. Two inches from the wall is safe; however, four inches allows better access to remove the rear panel. The vertical portion of the vent should be three to five feet high. This vertical section will provide natural draft in the event of a power failure.

#2 Preferred method

This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to five feet high and at least three inches from a combustible wall. This vertical sec- tion will provide natural draft in the event of a power failure.

If the stove is installed below grade the vent termination should be at least 1 foot above grade.

CAUTION

Keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building.

PC 45 Corn/Pellet Stove 9

Image 9
Contents Harman PC 45 Corn/Pellet Stove Installation & Operating ManualPC 45 Corn/Pellet Stove Introduction Table of ContentsInstalling rear cover panels Assembly and InstallationUnpacking FirebrickAssembling the door Door Assembly/Installation TipsInstallation InstallingMobile Home Installation With outside air installed With outside air installed, 6 feetVenting Outside Air Vent Pipe#2 Preferred method #1 Preferred method#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimumflue vent configuration #7 Installing through the ceiling ventIgniter switch to Auto Stove Temperature ModeAutomatic IGNITION/OPERATION Starting the Fire Automatic Start UPManual IGNITION/OPERATION Manual Stove Temperature Mode Igniter Switch to ManualManual Start UP Shut-Down ProcedureBurning Corn Burning PelletsAutomatic Ignition ESP Control Status light error messagesLow Draft Voltage Adjustment Low Draft Voltage AdjustmentMaintenance CleaningRemoving Ashes Soot and Fly Ash Cleaning of Feeder Fines AreaMaintenance Burn Pot Burn Pot Cleaning and MaintenanceCleaning of Burnpot Parts Cleaning Burn Pot PC 45 Trouble-ShootingHelpful Hints FuelSpecifications Feeder and SpecificationsCleaning Gold Door OptionsSunrise Gold Trim Gold Door Options Room Sensor Installation Hopper ExtensionSide Heat Shields Optional Pellet Burnpot GratePC 45 Wiring Diagram Description Part Number PC 45 Parts ListYear Limited Warranty Commercial