Harman Stove Company PC 45 manual Automatic Ignition ESP Control, Status light error messages

Page 17

AUTOMATIC IGNITION ESP CONTROL

Power Light Indicates power to the control.

Status Light

Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down. Blinks to indicate errors listed below.

Indicates power to distribution blower.

Indicates power to combustion blower

Indicates power to the feed motor.

Indicates igniter is on.

Temp dial

Allows you to adjust the room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit. It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7.

Dealer Diagnostic Port For dealermaintenance use only. Requires special DDM monitor supplied to Harman Dealers exclusively.

Feed adjuster Sets the maximum feed rate

Test

Runs all motors atfull speed for one minute to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remind you that you are still in "Test Mode".

Igniter switch

Setto appropriate

Start-Up mode.

Distribution Blower speed adjustmentrange. L = low

H = high

Variable speed anywhere between L and H; although as the stove temp. goes up , so does the L and H scale.

Mode Selector

Allows you to choose between Room Temp Mode, Stove Temp Mode, or OFF. Also allows you to vary the distribution blower speed by turning the knob to the high or lowside of each mode.

Status light error messages:

1 Blink: Indicates control board self diagnostic fail- ure. This requires a manual reset*.

3 Blinks: Indicates ESP (Exhaust Sensing Probe) failure. This requires a manual reset*.

4 Blinks: Can occur only in Room Temp Mode and indicates Room Sensing Probe failed or not installed. If a Room Sensing Probe is then installed, the sta- tus light will automatically reset.

NOTE: Unit will not start in "AUTO" with this status error.

5 Blinks (In Igniter Auto. Mode Only): Indicates that the unit has failed to light within the 45 minute start cycle. To reset - Turn Mode Selector to "OFF", then turn to either mode again.

6 Blinks : Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 minutes. See Troubleshooting section for more details.

A six blink status may be set if the stove is allowed to run out of pellets. To reset, turn mode selector to "OFF" then back on to the desired mode. If the unit was not out of pellets, see Troubleshooting section, Page 24, for more details.

*Manual reset- Disconnect power cord for a few seconds and reconnect. If error still occurs call your Harman Dealer.

PC 45 Corn/Pellet Stove 17

Image 17
Contents Harman PC 45 Corn/Pellet Stove Installation & Operating ManualPC 45 Corn/Pellet Stove Introduction Table of ContentsInstalling rear cover panels Assembly and InstallationUnpacking FirebrickAssembling the door Door Assembly/Installation TipsMobile Home Installation InstallationInstalling Venting With outside air installedWith outside air installed, 6 feet Outside Air Vent Pipe#2 Preferred method #1 Preferred method#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimumflue vent configuration #7 Installing through the ceiling ventAutomatic IGNITION/OPERATION Igniter switch to AutoStove Temperature Mode Starting the Fire Automatic Start UPManual IGNITION/OPERATION Manual Stove Temperature Mode Igniter Switch to ManualManual Start UP Shut-Down ProcedureBurning Corn Burning PelletsAutomatic Ignition ESP Control Status light error messagesLow Draft Voltage Adjustment Low Draft Voltage AdjustmentRemoving Ashes MaintenanceCleaning Soot and Fly Ash Cleaning of Feeder Fines AreaCleaning of Burnpot Parts Maintenance Burn PotBurn Pot Cleaning and Maintenance Cleaning Burn Pot PC 45 Trouble-ShootingHelpful Hints FuelSpecifications Feeder and SpecificationsSunrise Gold Trim Gold Door Cleaning GoldDoor Options Options Room Sensor Installation Hopper ExtensionSide Heat Shields Optional Pellet Burnpot GratePC 45 Wiring Diagram Description Part Number PC 45 Parts ListYear Limited Warranty Commercial