AUTOMATIC START UP

Fig. 23

14 PC 45 Corn/Pellet Stove

Starting the Fire

Igniter Switch to"AUTO"(up position)

Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit. Anytime there is interruption in power at the receptacle, the combustion blower will run for 1 minute after the power is regained.

1.Turn the Mode Selector to "OFF"

2.Fill the hopper with corn or pellets.

3.Clean the burn pot and housing, if necessary.

4.If starting after an empty hopper, turn the feed adjuster to "TEST" until the fuel is visible in the auger tube opening. This also allows you to check the motors for operation.

NOTE: The auger motor will not operate with the view door or ash door open.

NOTE: The initial start-up on a new stove may require the corn to be purged into the burnpot area before continuing to step 5.

5.Turn the feed adjuster to #2 (corn) or #4 (pellet)

6.Flip the igniter switch up into the "AUTO" position.

7.Turn the temperature dial to the desired room temperature.

8.Turn the mode selector dial to Room Temperature or Stove Temperature.

9.Fill the hopper with corn or pellets and remove the ashes as required.

Warning

"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP " A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE".

Image 14
Contents Installation & Operating Manual Harman PC 45 Corn/Pellet StovePC 45 Corn/Pellet Stove Table of Contents IntroductionUnpacking Assembly and InstallationInstalling rear cover panels FirebrickDoor Assembly/Installation Tips Assembling the doorMobile Home Installation InstallationInstalling Venting With outside air installedWith outside air installed, 6 feet Vent Pipe Outside Air#1 Preferred method #2 Preferred method#3 Installing into an existing Chimney US only #4 Installing into an existing fireplace chimney US only#6 Installing into an existing chimney US and Canada #7 Installing through the ceiling vent Minimumflue vent configurationAutomatic IGNITION/OPERATION Igniter switch to AutoStove Temperature Mode Automatic Start UP Starting the FireManual Stove Temperature Mode Igniter Switch to Manual Manual IGNITION/OPERATIONBurning Corn Shut-Down ProcedureManual Start UP Burning PelletsStatus light error messages Automatic Ignition ESP ControlLow Draft Voltage Adjustment Low Draft Voltage AdjustmentRemoving Ashes MaintenanceCleaning Cleaning of Feeder Fines Area Soot and Fly AshCleaning of Burnpot Parts Maintenance Burn PotBurn Pot Cleaning and Maintenance Helpful Hints PC 45 Trouble-ShootingCleaning Burn Pot FuelFeeder and Specifications SpecificationsSunrise Gold Trim Gold Door Cleaning GoldDoor Options Side Heat Shields Room Sensor Installation Hopper ExtensionOptions Optional Pellet Burnpot GratePC 45 Wiring Diagram PC 45 Parts List Description Part NumberYear Limited Warranty Commercial