MANUAL IGNITION/OPERATION

The PC45 Corn/Pellet Stove is capable of manual operation. This also allows the op- erator to manually control operation during an emergency (i.e. ignitor failure, when using a 502H battery backup, or when using certain generators.)

The unit can be switched between "AUTO" and "MANUAL" at any time during operation.

NOTE: When starting the unit in the "AUTO" mode and switching to "MANUAL", the fire must be large enough to turn the ignitor light off (located on the control board). This is a signal that the start cycle is completed and the fire will not go out.

Fig. 24: Room Temperature Mode: This setting will produce a room temperature of 70 degrees with the distribution blower at medium speed.

Manual Stove Temperature Mode

O

O

Igniter Switch to "MANUAL"

Room Temperature Mode

The fire will have to be lit with starting gel and a match, or started automatically, see "Automatic Op- eration". Turn to "Manual" position when the fire is es- tablished.

The difference between "AUTO" Room Tempera- ture Mode and "Manual" Room Temperature Mode is that the fire will not go out as the room temperature goes above the control board setting. The unit can only go to low burn and will remain there until it runs out of fuel or until more heat is needed and the feed rate in- creases. Feed rate adjustments and dial settings are the same as "AUTO" settings.

Igniter Switch to "MANUAL"

Stove Temperature Mode

The advantage of this mode is to allow the opera- tor to have a large viewing fire without blowing extra heat into the room.

During operation, with the temperature dial set at #5 or less, the distribution fan will not operate. A #5 on the temperature dial and a #5 on the feed adjuster is approximately 80% output. It is not necessary to oper- ate the distribution blower below this point. Therefore, there can be a higher feed rate ( a larger viewing fire) without an excess of hot air blowing into the room.

An example of when to use the Manual Stove Tem- perature Mode is if you want to watch a large fire and the room is already up to temperature. The Stove Tem- perature Mode allows you to have a larger fire and a lower sound level, without the distribution blower.

NOTE: During the use of this mode, if you keep increasing the temperature dial setting to in- crease the fire size, the distribution blower will au- tomatically come on when the ESP Temperature reaches 350o F, or 81% output.

Fig. 25: This setting will produce a large viewing fire without a distribution blower operating.

PC 45 Corn/Pellet Stove 15

Image 15
Contents Harman PC 45 Corn/Pellet Stove Installation & Operating ManualPC 45 Corn/Pellet Stove Introduction Table of ContentsFirebrick Assembly and InstallationInstalling rear cover panels UnpackingAssembling the door Door Assembly/Installation TipsInstallation InstallingMobile Home Installation With outside air installed With outside air installed, 6 feetVenting Outside Air Vent Pipe#2 Preferred method #1 Preferred method#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimumflue vent configuration #7 Installing through the ceiling ventIgniter switch to Auto Stove Temperature ModeAutomatic IGNITION/OPERATION Starting the Fire Automatic Start UPManual IGNITION/OPERATION Manual Stove Temperature Mode Igniter Switch to ManualBurning Pellets Shut-Down ProcedureManual Start UP Burning CornAutomatic Ignition ESP Control Status light error messagesLow Draft Voltage Adjustment Low Draft Voltage AdjustmentMaintenance CleaningRemoving Ashes Soot and Fly Ash Cleaning of Feeder Fines AreaMaintenance Burn Pot Burn Pot Cleaning and MaintenanceCleaning of Burnpot Parts Fuel PC 45 Trouble-ShootingCleaning Burn Pot Helpful HintsSpecifications Feeder and SpecificationsCleaning Gold Door OptionsSunrise Gold Trim Gold Door Optional Pellet Burnpot Grate Room Sensor Installation Hopper ExtensionOptions Side Heat ShieldsPC 45 Wiring Diagram Description Part Number PC 45 Parts ListYear Limited Warranty Commercial