Harman Stove Company Comprehensive Manual for Harman PC45 Feeder and Specifications

Page 23

P61A Feeder

Feeder and Specifications

Feeder Body Weldment

Pusher Arm MTNG. Nuts(2)1-10-02681Differential Switch: 3-20-9301

3-30-80252013

Slide Plate

Slab Base T-nut:: 3-31-23756186

1-10-08037

 

Pillow Block Bearing

Igniter Element: 3-20-02677

Igniter Mounting Bracket: 2-00-724121

3-31-3614087

 

 

3/8 MPT x 1/4" Barb Brass Inlet Fitting: 3-10-724203

 

Auger : 3-50-00465

 

Bearing Retainer: 2-00-04035

 

Auger Mounting Bolts: 3-30-1311812513

 

Pusher Arm Mtng.

 

 

Bolts(4)

 

Cam Block Assembly: 1-10-00381

 

 

3-30-2252005013

 

 

Cast Cover Gasket

 

Includes: Cam Bearing

 

 

 

Cam Block

 

5/16" Wingnut

3-44-00659

 

Cam to Auger Bolt

 

3-30-8131181

Pusher Arm Weldment

 

 

 

Air Pump: 3-20-02679

Gearmotor Assembly: 1-10-00697

 

1-10-08535

 

Cast Cover Assembly

 

Air Pump Mounting Hardware :

Includes: Motor Mount

 

1-10-00894

BHSCS 8'32 x 1/4: 3-30-3108320252

Rubber Grommet

 

 

 

 

Gear Motor

 

 

 

Specifications

 

 

 

 

 

23.5"

 

34.5"

 

32.375"

 

 

12.375"

9"

 

 

5.250"

Weight

249 lbs.

Blower

135 cfm

Feed Rate

0 to 5.0 lbs. per hr.

Hopper Capacity

80 lbs.

Fuel

Corn & Wood Pellets

Flue Size

3 inch

Outside Air Size

2 3/8" I.D.

Fuse Rating

6 amp

29.5"

PC 45 Corn/Pellet Stove 23

Image 23
Contents Harman PC 45 Corn/Pellet Stove Installation & Operating ManualPC 45 Corn/Pellet Stove Introduction Table of ContentsFirebrick Assembly and InstallationInstalling rear cover panels UnpackingAssembling the door Door Assembly/Installation TipsMobile Home Installation InstallationInstalling Venting With outside air installedWith outside air installed, 6 feet Outside Air Vent Pipe#2 Preferred method #1 Preferred method#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimumflue vent configuration #7 Installing through the ceiling ventAutomatic IGNITION/OPERATION Igniter switch to AutoStove Temperature Mode Starting the Fire Automatic Start UPManual IGNITION/OPERATION Manual Stove Temperature Mode Igniter Switch to ManualBurning Pellets Shut-Down ProcedureManual Start UP Burning CornAutomatic Ignition ESP Control Status light error messagesLow Draft Voltage Adjustment Low Draft Voltage AdjustmentRemoving Ashes MaintenanceCleaning Soot and Fly Ash Cleaning of Feeder Fines AreaCleaning of Burnpot Parts Maintenance Burn PotBurn Pot Cleaning and Maintenance Fuel PC 45 Trouble-ShootingCleaning Burn Pot Helpful HintsSpecifications Feeder and SpecificationsSunrise Gold Trim Gold Door Cleaning GoldDoor Options Optional Pellet Burnpot Grate Room Sensor Installation Hopper ExtensionOptions Side Heat ShieldsPC 45 Wiring Diagram Description Part Number PC 45 Parts ListYear Limited Warranty Commercial