Harman Stove Company Advance Pellet Stove manual Low Draft Voltage Adjustment

Page 10

Low Draft Voltage Adjustment

Combustion Motor Speed Control

Low draft only set point.

The small straight screwdriver slot is plastic; therefore, the unit can be adjusted while in operation.

Fig.15: Draft Meter bolt hole location

Fig.14

These units are pre-tested at the factory with exactly 120 Volts A.C., 60 Hz. They are checked and adjusted for firebox tightness, gasket leakage, motor operation and igniter operation. The Advance is then factory set at a mid-point adjustment and in most cases will not need any adjustments. NOTE: The factory low draft setting may not be correct for the unit's permanent installation conditions.

The control board on the Advance is equipped with a low draft adjustment port. Located on the control face just to the right of the igniter light. See Figure 14. This voltage adjustment is provided to allow the unit to be adjusted for the household voltage where the unit is going to be in permanent operation. NOTE: The line voltage varies from area to area and often home to home.

The low draft voltage should be adjusted to achieve the most efficient burn on low burn or "maintenance". This voltage adjustment allows the installer to change the lowvoltage set point approximately 15 volts. This adjustment should be done by the installer during set up because a draft meter reading isrequired to insure proper set up.

If the unit is not adjusted properly, it does not cause a safety concern. If the unit is adjusted too high, only effiency is lost. If the unit is adjusted too low, the low draft pressure switch will not allow the feeder motor or the igniter to operate.

A simple draft test should be performed after completing the flue pipe installation. To record the results for future reference:

1.Plug unit into a 120VAC, 60 HZ outlet.

2.Close the hopper lid, front view door, and the ash pan. Neither pellets or a fire are required for this test.

3.With the mode selector in the "OFF" position, turn the feed adjuster to "TEST".

4.Record the high draft_____in W.C. (Normal is -.50 to -.60) The control will be on the High Draft for a total of 2 minutes.

5.After 2 minutes is up, the combustion motor will go down to low draft and the distribution blower will go on high. Allow approximately 15 seconds to pass for the combustion motor to slow before checking the low draft.

6.If the low draft is between .35 and .45, record the reading _____ in W.C. If the reading is higher, slowly turn the set screw counter-clockwise until the draft lowers. If the reading is lower, very slowly turn the set screw clockwise until the draft increases.

NOTE: The test mode alternates from high to low draft every 60 seconds. If more time is needed for draft adjustment, wait until the next low draft cycle.

NOTE: In some cases, the draft may not go as low as .35 even with the set screw completelycounter- clockwise.

MODIFICATIONS

High Altitude (7,000 - 10,000 ft.)A combustion fan blade change can be made by an authorized Harman Dealer. These changes must be done with the use of a draft meter. These changes affect the low and high burn rate air to fuel ratios.

10

Image 10
Contents Installation & Operating Manual Harman Advance Pellet StoveTable of Contents IntroductionStove Temperature Mode Automatic Ignition/OperationTurn Mode Selector to OFF Battery Back UpIgniter Switch toAUTOup position Automatic Start UpIgniter Switch to Manual Manual Ignition/OperationManual Start Up Fill hopper with pellets and remove ashes as required.1Power Light Indicates power to the control Status Light ESP ControlInstallation Mobile Home InstallationPlacing Rear Shields Back on Unit Removing Side Doors for InstallationRemoving Side Doors Removing the Rear Motor Shield Sheet MetalLow Draft Voltage Adjustment Combustion Motor Speed Control Low draft only set pointRoom Sensor and Air Grill Installation Room Sensor Installation Gold Air Grill InstallationVent Pipe VentingOutside Air #2 Preferred method Vide natural draft in the event of a power failure#1 Preferred method This method also provides excellent venting for#3 Installing into an existing Chimney US only #4 Installing into an existing fireplace chimney US only#6 Installing into an existing chimney US and Canada #7 Installing through the ceiling vent Minimum flue vent configurationWith outside air installed, 6 feet With outside air installedRequirements for Terminating Venting Keep Combustibles Away From Flue Outlet Ash Pan Removal and Reattachment Maintenance Emptying AshesSoot and Fly Ash Opening Maintenance Cleaning Glass on View DoorOpening and Closing the View Door ClosingMaintenance Burn Pot Burn Pot Cleaning MaintenanceMaintenance Flame Guide and Brick Panel Flame Guide and Brick Panel Removal for CleaningMaintenance Combustion Intake Cover Cleaning and Maintenance for Combustion Intake CoverMaintenance Heat Exchanger Cleaning the Heat Exchanger SystemAdvance Motor & Component Locations Helpful Hints Trouble-ShootingCleaning Burn Pot FuelSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty