Harman Stove Company Advance Pellet Stove manual Specifications

Page 27

Specifications

7.750"

11.250"

 

5.250"

 

26.625"

 

32.5"

Weight

Blower

Hopper Capacity

Fuel

Outside Air Size

Fuse Rating

BTU Range

Feed Rate

Flue Size

Maximum Wattage

Start Cycle Wattage

Normal Run Wattage

20.5"

7.750"

C

L

250lbs.

135cfm

60lbs. Wood Pellets

23/8 inches

6amp

0to 48,000

1.0 lbs./hr. on minimum

6 lbs./ hr. on maximum

3inch Pellet Vent Pipe

480Watts (Start cycle and test)

340Watts

275Watts

27

Image 27
Contents Harman Advance Pellet Stove Installation & Operating ManualIntroduction Table of ContentsAutomatic Ignition/Operation Stove Temperature ModeAutomatic Start Up Battery Back UpIgniter Switch toAUTOup position Turn Mode Selector to OFFManual Ignition/Operation Igniter Switch to ManualFill hopper with pellets and remove ashes as required.1 Manual Start UpESP Control Power Light Indicates power to the control Status LightMobile Home Installation InstallationRemoving the Rear Motor Shield Sheet Metal Removing Side Doors for InstallationRemoving Side Doors Placing Rear Shields Back on UnitCombustion Motor Speed Control Low draft only set point Low Draft Voltage AdjustmentRoom Sensor Installation Gold Air Grill Installation Room Sensor and Air Grill InstallationVenting Vent PipeOutside Air This method also provides excellent venting for Vide natural draft in the event of a power failure#1 Preferred method #2 Preferred method#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimum flue vent configuration #7 Installing through the ceiling ventWith outside air installed With outside air installed, 6 feetRequirements for Terminating Venting Keep Combustibles Away From Flue Outlet Maintenance Emptying Ashes Ash Pan Removal and ReattachmentSoot and Fly Ash Closing Maintenance Cleaning Glass on View DoorOpening and Closing the View Door OpeningBurn Pot Cleaning Maintenance Maintenance Burn PotFlame Guide and Brick Panel Removal for Cleaning Maintenance Flame Guide and Brick PanelCleaning and Maintenance for Combustion Intake Cover Maintenance Combustion Intake CoverCleaning the Heat Exchanger System Maintenance Heat ExchangerAdvance Motor & Component Locations Fuel Trouble-ShootingCleaning Burn Pot Helpful HintsSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty