Harman Stove Company Advance Pellet Stove manual ESP Control

Page 7

ESP Control

Power Light Indicates power to the control.

Status Light

Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down. Blinks to indicate errors listed below.

Indicates power to distribution blower.

Indicates power to combustion blower

Indicates power to the feed motor.

Indicates power to the igniter.

Temp dial

Allows you to adjust the room temperature in Room Temp Mode using the outer scale marked in degrees Fahrenheit. It also allows you to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7.

Dealer Diagnostic Port

For dealer maintenance only. Requires special DDM monitor supplied to Harman Dealers exclusively.

Feed adjuster Sets the maximum feed rate

Test

Runs all motors atfull speed for one minute to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remind you that you are still in "Test Mode".

Igniter switch

Setto appropriate

Start-Up mode.

Distribution Blower speed adjustmentrange. L = low

H = high

Variable speed anywhere between L and H; although as the stove temp. goes up , so does the low end of the scale.

Mode Selector

Allows you to choose between RoomTemp Mode,Stove Temp Mode, or OFF. Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode.

Status light error messages:

1 Blink: Indicates control board self diagnostic failure. This requires a manual reset*.

3 Blinks: Indicates ESP (Exhaust Sensing Probe) fail- ure. This requires a manual reset*.

4Blinks: Can occur only in Room Temp Mode and indi- cates Room Sensing Probe failed or not installed. If a Room Sensing Probe is then installed, the status light will automatically reset.

NOTE: Unit will not start in "AUTO" with this status error.

5Blinks (In Igniter Auto. Mode Only): Indicates that the unit has failed to light after 4 consecutive igniter cycles, 32 minutes total. To reset - Turn Mode Selector to "OFF", then turn to either mode again.)

6 Blinks : Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 min- utes. See Troubleshooting section for more details.

A six blink status may be set if the stove is allowed to run out of pellets. To reset, turn mode selector to "OFF" then back on to the desired mode. If the unit was not out of pel- lets, see Troubleshooting section for more details.

*Manual reset- disconnect power cord for a few seconds and reconnect. If error still occurs call your Dealer. NOTICE: When power is given to the stove, the control board willblink a fewtimes toindicate current versionof controlboard. This should not be confused with error messages.

7

Image 7 Contents
Harman Advance Pellet Stove Installation & Operating ManualIntroduction Table of Contents Automatic Ignition/Operation Stove Temperature ModeAutomatic Start Up Battery Back UpIgniter Switch toAUTOup position Turn Mode Selector to OFFManual Ignition/Operation Igniter Switch to ManualFill hopper with pellets and remove ashes as required.1 Manual Start UpESP Control Power Light Indicates power to the control Status LightMobile Home Installation InstallationRemoving the Rear Motor Shield Sheet Metal Removing Side Doors for InstallationRemoving Side Doors Placing Rear Shields Back on UnitCombustion Motor Speed Control Low draft only set point Low Draft Voltage AdjustmentRoom Sensor Installation Gold Air Grill Installation Room Sensor and Air Grill InstallationVent Pipe VentingOutside Air This method also provides excellent venting for Vide natural draft in the event of a power failure#1 Preferred method #2 Preferred method#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimum flue vent configuration #7 Installing through the ceiling ventWith outside air installed, 6 feet With outside air installedRequirements for Terminating Venting Keep Combustibles Away From Flue Outlet Ash Pan Removal and Reattachment Maintenance Emptying AshesSoot and Fly Ash Closing Maintenance Cleaning Glass on View DoorOpening and Closing the View Door OpeningBurn Pot Cleaning Maintenance Maintenance Burn PotFlame Guide and Brick Panel Removal for Cleaning Maintenance Flame Guide and Brick PanelCleaning and Maintenance for Combustion Intake Cover Maintenance Combustion Intake CoverCleaning the Heat Exchanger System Maintenance Heat ExchangerAdvance Motor & Component Locations Fuel Trouble-ShootingCleaning Burn Pot Helpful HintsSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty