Harman Stove Company Advance Pellet Stove manual Mobile Home Installation

Page 8

Installation

Wheninstalling and operating your HarmanAdvance Pellet Stove, respect basic safety standards. Read these instructions carefully before you attempt to install or oper- ate the Advance. Failure to do so may result in damage to property or personal injury and may void the product war- ranty.

Consult with your local building code agency and in- surance representative before you begin your installation to ensure compliance with local codes, including the need for permits and follow-up inspections.

Several issues must be addressed when selecting a suitable location for your Advance Pellet Stove. Observ- ing requiredclearances to combustible materials, the prox- imity to a safe chimney or venting system, and the acces- sibility of electrical supply must all be considered. In addi- tion, selecting a location that takes advantage of the building's natural air flow is also desirable to maximize the heating effectiveness of the heater. In many cases, this is a central location within the building.

Adequate combustionand ventilationair must be pro- vided.

Place the stove on a noncombustible floor or UL ap- proved floor protector that extends 6 inches to the front, 6 inches to the sides and 1 inch to the rear of the stove. Fig. 8.

Place the stove away from combustible walls at least as far as shown in figures 6, and 7.

Note that the clearances shown are minimum for safety but do not leave much roomfor access when clean- ing or servicing. Please take this into account when plac- ing the stove.

Mobile Home Installation

When installing this stove in a mobile home several requirements must be followed:

1.The unit must be bolted to the floor. This can be done with 1/4" lag screws throught the 2 holes in

the base plate shown in Fig. 13, Page 9.

2.The unit must also be connected for the outside air. See page 12.

3.Floor protection and clearances must be followed as shown above.

4.Unit must be grounded to the metal frame of the mobile home.

CAUTION: This appliance must be vented to the outside.

Due to hightemperatures, the stove shouldbe placed out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn to skin and/or clothing.

Young children should be carefully supervised when they are in the same room as the stove.

Clothing and other flammable materials should not be placed on or near the stove.

7"

7"

Fig.6

1"

10"

FLOOR PROTECTOR

Fig.7

1"

6"

6"

FLOOR

PROTECTOR 6"

Fig.8

Installation and repair of this stove should be done by a qualified service person. The appliance should be in- spected before use and at least annually by a qualified service person. More frequent cleaning will be required. It is imperative that control compartments, burners, and cir- culating air passageways of the stove be kept clean.

AFTER THE INSTALLATION IS COMPLETED Before the first fire is lit, check and record

the high and low draft reading numbers on page

10.Make adjustments to the low draft at this time, if necessary. See page 10.

8

Image 8
Contents Installation & Operating Manual Harman Advance Pellet StoveTable of Contents IntroductionStove Temperature Mode Automatic Ignition/OperationBattery Back Up Igniter Switch toAUTOup positionTurn Mode Selector to OFF Automatic Start UpIgniter Switch to Manual Manual Ignition/OperationManual Start Up Fill hopper with pellets and remove ashes as required.1Power Light Indicates power to the control Status Light ESP ControlInstallation Mobile Home InstallationRemoving Side Doors for Installation Removing Side DoorsPlacing Rear Shields Back on Unit Removing the Rear Motor Shield Sheet MetalLow Draft Voltage Adjustment Combustion Motor Speed Control Low draft only set pointRoom Sensor and Air Grill Installation Room Sensor Installation Gold Air Grill InstallationOutside Air VentingVent Pipe Vide natural draft in the event of a power failure #1 Preferred method#2 Preferred method This method also provides excellent venting for#3 Installing into an existing Chimney US only #4 Installing into an existing fireplace chimney US only#6 Installing into an existing chimney US and Canada #7 Installing through the ceiling vent Minimum flue vent configurationRequirements for Terminating Venting With outside air installedWith outside air installed, 6 feet Keep Combustibles Away From Flue Outlet Soot and Fly Ash Maintenance Emptying AshesAsh Pan Removal and Reattachment Maintenance Cleaning Glass on View Door Opening and Closing the View DoorOpening ClosingMaintenance Burn Pot Burn Pot Cleaning MaintenanceMaintenance Flame Guide and Brick Panel Flame Guide and Brick Panel Removal for CleaningMaintenance Combustion Intake Cover Cleaning and Maintenance for Combustion Intake CoverMaintenance Heat Exchanger Cleaning the Heat Exchanger SystemAdvance Motor & Component Locations Trouble-Shooting Cleaning Burn PotHelpful Hints FuelSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty