Harman Stove Company Advance Pellet Stove Maintenance Burn Pot, Burn Pot Cleaning Maintenance

Page 21

Maintenance - Burn Pot

Fig. 38

Fig. 39

Burn Pot Cleaning and

Maintenance

1.Scrape the top holed surface and sides of the burn pot.(Fig 38) It is not necessary to completely remove all material from the burn pot. The excess will be pushed out during the next use.

2.Loosen the (2) wing thumb screws on the lower front angle of the burn pot. (Fig. 38)

3.Lift off the clean-out cover (Fig.39) to open the bottom clean-out chamber. (Fig.40)

DANGER

Disconnect the power to the unit before

removing cover.

4.Clean ash buildup from inside the chamber while cover is off. Use the scraper to tap on the top front edge of the burn pot. This will help knock pieces of ash, loosened by the scraping process, down through the holes. It also helps knock scale off of the igniter element.

Figure 40

The igniter is made to be removable for service by insulated male/female wire connectors. These connections between the hot leads (the wires inside the burn pot) and the cold leads (the wires from the control board) are always pulled to the rear of the feeder body.(Not coiled inside the burn pot.)

It is very important that these connections are to the inside rear of the feeder body. Also, the extra wire of the igniter wire service loop must be pulled out through the rear of the feeder and tied up so that it will not be damaged by any moving

Burn pot igniter parts. See page 25.

DANGER

Disconnect the power to the unit before

removing cover.

Warning

Use caution when cleaning burn pot clean-

out chamber. Do not damage the high

temperature igniter wires.

Igniter hot lead wires (high temperature)

Fig. 40

Note: The hot lead/cold lead connection

must always be pulled to the rear of the

Viewed from below through the ash pan

feeder body before operation.

 

21

Image 21
Contents Harman Advance Pellet Stove Installation & Operating ManualIntroduction Table of ContentsAutomatic Ignition/Operation Stove Temperature ModeIgniter Switch toAUTOup position Battery Back UpTurn Mode Selector to OFF Automatic Start UpManual Ignition/Operation Igniter Switch to ManualFill hopper with pellets and remove ashes as required.1 Manual Start UpESP Control Power Light Indicates power to the control Status LightMobile Home Installation InstallationRemoving Side Doors Removing Side Doors for InstallationPlacing Rear Shields Back on Unit Removing the Rear Motor Shield Sheet MetalCombustion Motor Speed Control Low draft only set point Low Draft Voltage AdjustmentRoom Sensor Installation Gold Air Grill Installation Room Sensor and Air Grill InstallationVenting Vent PipeOutside Air #1 Preferred method Vide natural draft in the event of a power failure#2 Preferred method This method also provides excellent venting for#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimum flue vent configuration #7 Installing through the ceiling ventWith outside air installed With outside air installed, 6 feetRequirements for Terminating Venting Keep Combustibles Away From Flue Outlet Maintenance Emptying Ashes Ash Pan Removal and ReattachmentSoot and Fly Ash Opening and Closing the View Door Maintenance Cleaning Glass on View DoorOpening ClosingBurn Pot Cleaning Maintenance Maintenance Burn PotFlame Guide and Brick Panel Removal for Cleaning Maintenance Flame Guide and Brick PanelCleaning and Maintenance for Combustion Intake Cover Maintenance Combustion Intake CoverCleaning the Heat Exchanger System Maintenance Heat ExchangerAdvance Motor & Component Locations Cleaning Burn Pot Trouble-ShootingHelpful Hints FuelSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty