Harman Stove Company Advance Pellet Stove manual Maintenance Heat Exchanger

Page 24

Maintenance - Heat Exchanger

Fig. 49

Fig. 50

Fig. 51

Fig. 52

Slot

Tab

Hook Tab

Center Lock

Center Lock

Top Accordian Heat Exchangers

Rear Firewall Heat Exchanger

Cleaning the Heat Exchanger

System

1.Removebrick panel andflameguide. See Pg22.

2.Remove the ash pan. See Page 19.

3.Remove flue baffles located on each side of the burnpot, see Fig. 49 & 50. The baffle is held in place by inserting the tab into the slot (located toward the outside of the firebox) and resting it on the hook tab located beside the burnpot.

4.Pull the pointed end of the baffle slightly front with one hand while pushing up from below with the other hand. See Fig. 50.

5.With the baffle released from the tabs, rotate the pointed end toward the door opening. Lift baffle up and out.

The right and left baffle are interchangeable.

6.Now remove the heat exchanger baffle plates. See Fig. 51 & 52. To remove the left plate, slide the center lock to the right. To remove the right plate, slide the center lock to the left. (The right and left plates are interchangeable.)

This will allow access to all of the rear vertical heat exchanger surfaces.

7.With all four baffle plates removed, cleaning can be performed with the arrow end of the scraper. See Fig. 53.

8.Scrape all of the heat exchanger surfaces.(Be sure to clean any internal ledges where fly ash could have collected.)

Fig. 53

24

Image 24
Contents Installation & Operating Manual Harman Advance Pellet StoveTable of Contents IntroductionStove Temperature Mode Automatic Ignition/OperationBattery Back Up Igniter Switch toAUTOup positionTurn Mode Selector to OFF Automatic Start UpIgniter Switch to Manual Manual Ignition/OperationManual Start Up Fill hopper with pellets and remove ashes as required.1Power Light Indicates power to the control Status Light ESP ControlInstallation Mobile Home InstallationRemoving Side Doors for Installation Removing Side DoorsPlacing Rear Shields Back on Unit Removing the Rear Motor Shield Sheet MetalLow Draft Voltage Adjustment Combustion Motor Speed Control Low draft only set pointRoom Sensor and Air Grill Installation Room Sensor Installation Gold Air Grill InstallationVenting Vent PipeOutside Air Vide natural draft in the event of a power failure #1 Preferred method#2 Preferred method This method also provides excellent venting for#3 Installing into an existing Chimney US only #4 Installing into an existing fireplace chimney US only#6 Installing into an existing chimney US and Canada #7 Installing through the ceiling vent Minimum flue vent configurationWith outside air installed With outside air installed, 6 feetRequirements for Terminating Venting Keep Combustibles Away From Flue Outlet Maintenance Emptying Ashes Ash Pan Removal and ReattachmentSoot and Fly Ash Maintenance Cleaning Glass on View Door Opening and Closing the View DoorOpening ClosingMaintenance Burn Pot Burn Pot Cleaning MaintenanceMaintenance Flame Guide and Brick Panel Flame Guide and Brick Panel Removal for CleaningMaintenance Combustion Intake Cover Cleaning and Maintenance for Combustion Intake CoverMaintenance Heat Exchanger Cleaning the Heat Exchanger SystemAdvance Motor & Component Locations Trouble-Shooting Cleaning Burn PotHelpful Hints FuelSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty