Harman Stove Company Advance Pellet Stove manual Requirements for Terminating Venting

Page 17

Venting

Requirements for Terminating the

Venting

WARNING: Venting terminals must not be re- cessed into a wall or siding.

NOTE: Only PL vent pipe wall pass-throughs and fire stops should be used when venting through com- bustible materials.

NOTE: Always take into consideration the effect the prevailing wind direction or other wind currents will cause with flyash and /or smoke when placing the ter- mination.

In addition, the following must be observed: A. The clearance above grade must be a mini-

mum of 18".1

B. The clearance to a window or door that may be opened must be a minimum of 48" to the side, 48" below the window/door, and 12" above the window/ door.1

( with outside air installed, 18” )

C. A 12" clearance to a permanently closed win- dow is recommended to prevent condensation on the window.

D. The vertical clearance to a ventilated soffit lo- cated above the terminal within a horizontal distance of 2 feet (60 cm) from the center-line of the terminal must be a minimum of 18".

E. The clearance to an unventilated soffit must be a minimum of 12".

F. The clearance to an outside corner is 11" from center of pipe.

G. The clearance to an inside corner is 12".

H.A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when mea- sured from the horizontal center-line of the regulator.1

I. The clearance to service regulator vent outlet must be a minimum of 6 feet.1

J. The clearance to a non-mechanical air sup-

ply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48”.1

K. The clearance to a mechanical air supply inlet must be a minimum of 10 feet.1

(with outside air installed, 6 feet )

L. The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet.1,2

M. The clearance under a veranda, porch, deck or balcony must be a minimum of 12 inches.1,3

NOTE: The clearance to vegetation and other exterior combustibles such as mulch is 36” as mea- sured from the center of the outlet or cap. This 36”

radius continues to grade or a minimum of 7 feet below the outlet.

1Certain Canadian and or Local codes or regu- lations may require different clearances.

2A vent shall not terminate directly above a side- walk or paved driveway which is located between two single family dwellings and serves both dwell- ings.

3Only permitted if veranda, porch, deck, or bal- cony is fully open on a minimum of 2 sides beneath the floor.

NOTE: Where passage through a wall, or partition of combustible construction is desired, the installation shall conformto CAN/CSA-B365. (if in Canada)

I nsid e

Co rn er

De ta il

Fixed

 

 

Closed

Openable

Fixed

Openable

 

Closed

 

 

V

= Vent terminal

A = Air supply inlet

= Area where terminal is not permitted

17

Image 17
Contents Harman Advance Pellet Stove Installation & Operating ManualIntroduction Table of ContentsAutomatic Ignition/Operation Stove Temperature ModeIgniter Switch toAUTOup position Battery Back UpTurn Mode Selector to OFF Automatic Start UpManual Ignition/Operation Igniter Switch to ManualFill hopper with pellets and remove ashes as required.1 Manual Start UpESP Control Power Light Indicates power to the control Status LightMobile Home Installation InstallationRemoving Side Doors Removing Side Doors for InstallationPlacing Rear Shields Back on Unit Removing the Rear Motor Shield Sheet MetalCombustion Motor Speed Control Low draft only set point Low Draft Voltage AdjustmentRoom Sensor Installation Gold Air Grill Installation Room Sensor and Air Grill InstallationOutside Air VentingVent Pipe #1 Preferred method Vide natural draft in the event of a power failure#2 Preferred method This method also provides excellent venting for#4 Installing into an existing fireplace chimney US only #3 Installing into an existing Chimney US only#6 Installing into an existing chimney US and Canada Minimum flue vent configuration #7 Installing through the ceiling ventRequirements for Terminating Venting With outside air installedWith outside air installed, 6 feet Keep Combustibles Away From Flue Outlet Soot and Fly Ash Maintenance Emptying AshesAsh Pan Removal and Reattachment Opening and Closing the View Door Maintenance Cleaning Glass on View DoorOpening ClosingBurn Pot Cleaning Maintenance Maintenance Burn PotFlame Guide and Brick Panel Removal for Cleaning Maintenance Flame Guide and Brick PanelCleaning and Maintenance for Combustion Intake Cover Maintenance Combustion Intake CoverCleaning the Heat Exchanger System Maintenance Heat ExchangerAdvance Motor & Component Locations Cleaning Burn Pot Trouble-ShootingHelpful Hints FuelSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty