Maintenance - Cleaning Glass on View Door

Fig. 34

Fig. 35

Fig. 36

WARNING

Door latch may

be hot!

Receiving Bolt

Opening and Closing the View Door

Opening:

The view door must be opened for cleaning of the glass and scraping of the burn pot. This should be done with the unit off and cool, in most cases. Although the glass can be cleaned and burn pot scraped while the unit is at low burn.

1.Using scraper as shown in Fig. 34and 35, lift the door latch forward and up.

2.Swing the door open to the left, stopping the swing when resistance is felt. Forcing the door open further then was designed may cause damage to the door or it's hinges.

CAUTION

Do not put excessive downward pressure on the latch end of the door while in the open position.

If the door is going to be opened for an extended period of time, it is suggested that it be removed (see Fig. 36) and set safely aside.

3.Inspect the door gasket and glass gaskets for worn or missing pieces. Replace if necessary. (Fig. 37)

Closing:

When closing the door, always hold the door latch all the way up until it has caught the receiving bolt. Then push the latch downward and back until the door is fully seated. See Fig. 35.

Removing View Door:

To remove the view door from the stove, hold the door by the bottom and lift upward off of the hinge pins.See Fig. 36.

Inspect the door gasket.See Fig. 37.

REPLACE GLASS WITH

CERAMIC GLASS ONLY.

Fig. 37

20

Image 20
Contents Installation & Operating Manual Harman Advance Pellet StoveTable of Contents IntroductionStove Temperature Mode Automatic Ignition/OperationBattery Back Up Igniter Switch toAUTOup positionTurn Mode Selector to OFF Automatic Start UpIgniter Switch to Manual Manual Ignition/OperationManual Start Up Fill hopper with pellets and remove ashes as required.1Power Light Indicates power to the control Status Light ESP ControlInstallation Mobile Home InstallationRemoving Side Doors for Installation Removing Side DoorsPlacing Rear Shields Back on Unit Removing the Rear Motor Shield Sheet MetalLow Draft Voltage Adjustment Combustion Motor Speed Control Low draft only set pointRoom Sensor and Air Grill Installation Room Sensor Installation Gold Air Grill InstallationOutside Air VentingVent Pipe Vide natural draft in the event of a power failure #1 Preferred method#2 Preferred method This method also provides excellent venting for#3 Installing into an existing Chimney US only #4 Installing into an existing fireplace chimney US only#6 Installing into an existing chimney US and Canada #7 Installing through the ceiling vent Minimum flue vent configurationRequirements for Terminating Venting With outside air installedWith outside air installed, 6 feet Keep Combustibles Away From Flue Outlet Soot and Fly Ash Maintenance Emptying AshesAsh Pan Removal and Reattachment Maintenance Cleaning Glass on View Door Opening and Closing the View DoorOpening ClosingMaintenance Burn Pot Burn Pot Cleaning MaintenanceMaintenance Flame Guide and Brick Panel Flame Guide and Brick Panel Removal for CleaningMaintenance Combustion Intake Cover Cleaning and Maintenance for Combustion Intake CoverMaintenance Heat Exchanger Cleaning the Heat Exchanger SystemAdvance Motor & Component Locations Trouble-Shooting Cleaning Burn PotHelpful Hints FuelSpecifications Advance Wiring Diagram Advance Feeder Assembly Advance Parts List Harman Gold Warranty Harman Gold Warranty