Appendix D LEDs
Chassis and Module LEDs for the Cisco Nexus 5000 Series Switches
Se n d d o c u m e n t a t i o n c o m m e n t s t o n ex u s 5 k d o c s @ c i s c o . c o m .
Table | LEDs for the Cisco Nexus 5500 Platform Switches (continued) | |||
|
|
|
|
|
Component |
| LED | Status | Description |
|
|
|
| |
Expansion module | Status | On | All diagnostics pass. The module is operational. | |
|
|
| (green) |
|
|
|
|
|
|
|
|
| Off | The module is not receiving power. |
|
|
|
|
|
|
|
| Solid on | The module is booting or running diagnostics. |
|
|
| (amber) | An overtemperature condition has occurred. The |
|
|
|
| |
|
|
|
| temperature threshold has been exceeded by a |
|
|
|
| small value during environmental monitoring. |
|
|
|
|
|
|
|
| Blinking | An overtemperature condition has occurred. The |
|
|
| (amber) | temperature threshold has been exceeded by a |
|
|
|
| large value during environmental monitoring. |
|
|
|
| If the module fails during initial reset, the LED |
|
|
|
| continues to blink and the module does not come |
|
|
|
| online. |
|
|
|
| The module has runtime failure and is brought |
|
|
|
| offline. |
|
|
|
|
|
Port LED |
| Indicates LED | Off | The port is not active or the link is not connected. |
|
| status |
|
|
|
| Solid on | The port is active. The link is connected and | |
|
|
| ||
|
|
| (green) | operational. |
|
|
|
|
|
|
|
| Solid on | The module or port is disabled through the CLI |
|
|
| (amber) | command or the module is initializing. |
|
|
|
|
|
|
|
| Blinking | The port is faulty and has been disabled. |
|
|
| (amber) |
|
|
|
|
|
|
Table
Conditions Indicated by the Power Supply LEDs
You can determine the power supply conditions by combining the LED states of the OK and FAIL LEDs (see Table
Table | Power Supply LED Descriptions |
|
|
|
|
|
|
|
| OK LED | FAIL LED |
Power Supply Condition | (Green) | (Amber) | |
|
|
| |
No AC or DC power to all power supplies. | Off | Off | |
|
|
| |
Power supply failure, including over voltage, over current, over temperature, | Off | On | |
and fan failure. |
|
|
|
|
|
| |
Power supply warning events where the power supply continues to operate. | Off | Blinking | |
These events include high temperature, high power, and slow fan. |
|
| |
|
|
|
|
Cisco Nexus 5500 Platform and Cisco Nexus 5000 Platform Hardware Installation Guide
| ||
|