Appendix C Cable and Port Specifications
Supported Power Cords and Plugs
Se n d d o c u m e n t a t i o n c o m m e n t s t o n ex u s 5 k d o c s @ c i s c o . c o m .
Table
Table | Console Port Pinouts for the Cisco Nexus 5010 Switch | |
|
|
|
Pin | Signal | |
|
|
|
1 | RTS | |
|
|
|
2 | DTR | |
|
|
|
3 | TxD | |
|
|
|
4 | GND | |
|
|
|
5 | GND | |
|
|
|
6 | RxD | |
|
|
|
7 | DSR | |
|
|
|
8 | CTS | |
|
|
|
Supported Power Cords and Plugs
Note This section applies to the Cisco Nexus 5548 switch, the Cisco Nexus 5020 switch, and the Cisco Nexus 5010 switch.
Each power supply has a separate power cord. Standard power cords or jumper power cords are available for connection to a power distribution unit that has IEC 60320 C19 outlet receptacles. The standard power cords have an IEC C13 connector on the end that plugs into the switch. The optional jumper power cords, for use in cabinets, have an IEC C13 connector on the end that plugs into the switch and an IEC C14 connector on the end that plugs into an IEC C13 outlet receptacle.
Note Only the regular power cords or jumper power cords provided with the switch are supported.
Table
|
| Table | Power Cords for the Cisco Nexus 5020 Switch |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Length |
| Power Cord Reference | |||
|
|
|
|
|
| ||||
|
| Description |
| Feet | Meters | Illustration | |||
|
|
|
|
|
|
| |||
|
| 8.2 | 2.5 | Figure | |||||
|
| Power cord 250 VAC 10 A, IRAM 2073 plug |
|
|
|
|
|
| |
|
| Argentina |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 8.2 | 2.5 | Figure | ||||
|
| Power cord 250 VAC 10 A, 3112 plug, |
|
|
|
|
|
| |
|
| Australia |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| 8.2 | 2.5 | Figure | |||||
|
| Power cord 250 VAC 10 A, GB 2009 plug |
|
|
|
|
|
| |
|
| China |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|