Appendix D LEDs
Chassis and Module LEDs for the Cisco Nexus 5000 Series Switches
Se n d d o c u m e n t a t i o n c o m m e n t s t o n ex u s 5 k d o c s @ c i s c o . c o m .
Chassis and Module LED Descriptions
Table
|
|
|
| Table | LEDs for the Cisco Nexus 5500 Platform Switches | ||||
|
|
|
|
|
|
|
|
| |
|
|
|
| Component |
| LED | Status | Description | |
|
|
|
|
|
|
|
|
| |
|
|
|
| Chassis |
| ID | On | Identifies the chassis receiving the beacon signal. | |
|
|
|
| (front and back) | (Cisco Nexus 5500 | (blue) |
|
| |
|
|
|
|
|
| Platform only) |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Status | Solid on | All diagnostics pass. The module is operational. | |
|
|
|
|
|
|
| (green) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Off | The module is not receiving power. | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| On | The module is booting or running diagnostics. | |
|
|
|
|
|
|
| (amber) | An overtemperature condition has occurred. The | |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| temperature threshold has been exceeded by a | |
|
|
|
|
|
|
|
| small value during environmental monitoring. | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Blinking | An overtemperature condition has occurred. The | |
|
|
|
|
|
|
| (amber) | temperature threshold has been exceeded by a | |
|
|
|
|
|
|
|
| large value during environmental monitoring. | |
|
|
|
|
|
|
|
| If the module fails during initial reset, the LED | |
|
|
|
|
|
|
|
| continues to blink and the module does not come | |
|
|
|
|
|
|
|
| online. | |
|
|
|
|
|
|
|
| The module has a runtime failure and is brought | |
|
|
|
|
|
|
|
| offline. | |
|
|
|
|
|
|
|
|
| |
|
|
|
| Fan tray |
| Status | Solid on | All diagnostics pass. The module is operational. | |
|
|
|
| (front of chassis) |
| (green) |
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Off | The module is not receiving power. | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Solid on | The module is booting or running diagnostics. | |
|
|
|
|
|
|
| (amber) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Blinking | If the module fails during initial reset, the LED | |
|
|
|
|
|
|
| (amber) | continues to blink and the module does not come | |
|
|
|
|
|
|
|
| online. | |
|
|
|
|
|
|
|
| The module has runtime failure and is brought | |
|
|
|
|
|
|
|
| offline. | |
|
|
|
|
|
|
|
|
| |
|
|
|
| Power supply |
| OK (green) | Solid on | Power supply is on and okay. | |
|
|
|
| (front of chassis) |
|
|
|
| |
|
|
|
|
| Blinking | 3.3 voltage standby (VSB) is on but the power | |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| supply unit is not powering the other modules. | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Off | No AC power to the power supply. | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| FAULT (amber) | Solid on | Power supply failures, overvoltage, overcurrent, | |
|
|
|
|
|
|
|
| overtemperature. | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Blinking | AC is present, 3.3 VSB on, and the power supply | |
|
|
|
|
|
|
|
| is off. | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Off | Operating normally. | |
|
|
|
|
|
|
|
| ||
|
|
| Cisco Nexus 5500 Platform and Cisco Nexus 5000 Platform Hardware Installation Guide | ||||||
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||