Desa VP2600C, VP1600IT, VP1600C, VP2200IT Ventilation AIR, Ventilation Air From Outdoors

Page 8

FRESH AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR (Continued)

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

8

100751

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Features IdentificationLocal Codes UnpackingFresh AIR For CombustionVentilation Producing Adequate VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIRDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Fresh AIR for Combustion and VentilationVentilation AIR Ventilation AIR Ventilation Air From OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterThermostat Sensing Bulb Models VP1600IT and VP2200IT OnlyLocating Thermostat Sensing Bulb Attaching Thermostat Sensing BulbInstalling Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS Qualified service person must connect heater to gas supplySupply Follow all local codesPressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at onceConnecting Pressure Testing Heater GAS ConnectionsOperating Heater Operating Heater Lighting InstructionsHeater To Select Heating LevelShutting Off Heater Shutting Off Burner Only pilot stays litOperating If you do not follow these instructions exactly, a fire orModels VP1600C and VP2600C LOW MED High Inspecting Burner Pilot Flame PatternBurner Flame Pattern Cleaning MaintenanceTrouble Shooting ODS/PILOT and Burner OrificeCleaning and Mainte TroubleSee Cleaning TROUBLE- ShootingService TechnicalIf you smell gas Shut off gas supplyVP1600C VP2600C Service Publications HintsVP1600IT VP2200IT Replacement Parts AccessoriesIllustrated Parts Breakdown Model VP1600ITParts List KEY Part Number Description QTYModel VP2200IT Parts List Model VP1600C Control Position Label Model VP2600C Parts List Warranty Information Keep this Warranty