TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

Burner(s) does not

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

light after ODS/pilot is

 

clogged.

 

(see Cleaning and

lit.

 

 

 

Maintenance, page 26) or

 

 

 

 

replace burner orifice(s).

 

2.

Burner orifice(s)

2.

Replace burner orifice(s).

 

 

diameter is too small.

 

 

 

3.

Inlet gas pressure is too

3.

Contact local propane gas

 

 

low.

 

company.

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is too

1.

Contact local propane gas

burner(s)

 

low.

 

company.

 

2.

Burner orifice(s) is

2.

Clean burner orifice(s)

 

 

clogged.

 

(see Cleaning and

 

 

 

 

Maintenance, page 26 or

 

 

 

 

replace burner orifice(s).

 

 

 

 

 

Burner backfiring

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

during combustion.

 

clogged or damaged.

 

(see Cleaning and

 

 

 

 

Maintenance, page 26) or

 

 

 

 

replace burner orifice(s).

 

2.

Burner damaged.

2.

Replace burner.

 

3.

Gas regulator defective.

3.

Replace gas regulator.

 

 

 

 

 

Burner plaque(s) does

1.

Plaque damaged.

1.

Replace burner.

not glow.

2.

Inlet gas pressure is too

2.

Contact local propane gas

 

 

low.

 

company.

 

3.

Control knob set be-

3.

Turn control knob until it

 

 

tween locked positions.

 

locks at desired setting.

 

 

 

 

 

Slight smoke or odor

1.

Residues from manu-

1.

Problem will stop after a

during initial opera-

 

facturing processes

 

few hours of operation.

tion

 

 

 

 

 

 

 

 

 

Heater produces a

1.

Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling.

 

excessive, contact

or shut off.

 

 

 

qualified service person.

100751

Image 28
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Features IdentificationLocal Codes UnpackingFresh AIR For CombustionVentilation Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Fresh AIRDetermining if You Have a Confined or Unconfined Space Ventilation AIR Fresh AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation AIR Ventilation Air From OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterThermostat Sensing Bulb Models VP1600IT and VP2200IT OnlyLocating Thermostat Sensing Bulb Attaching Thermostat Sensing BulbInstalling Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS Qualified service person must connect heater to gas supplySupply Follow all local codesPressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at onceConnecting Pressure Testing Heater GAS ConnectionsOperating Heater Operating Heater Lighting InstructionsHeater To Select Heating LevelShutting Off Heater Shutting Off Burner Only pilot stays litOperating If you do not follow these instructions exactly, a fire orModels VP1600C and VP2600C LOW MED High Inspecting Burner Pilot Flame PatternBurner Flame Pattern Cleaning MaintenanceTrouble Shooting ODS/PILOT and Burner OrificeCleaning and Mainte TroubleSee Cleaning TROUBLE- ShootingService TechnicalIf you smell gas Shut off gas supplyVP1600IT VP2200IT Service Publications HintsVP1600C VP2600C Replacement Parts AccessoriesIllustrated Parts Breakdown Model VP1600ITParts List KEY Part Number Description QTYModel VP2200IT Parts List Model VP1600C Control Position Label Model VP2600C Parts List Warranty Information Keep this Warranty