FRESH AIR | DETERMINING | ||||||||
FOR | Determining if You Have a Confined or Unconfined Space | ||||||||
Use this worksheet to determine if you have a confined or unconfined space. | |||||||||
COMBUSTION | |||||||||
Space: Includes the room in which you will install heater plus any adjoining rooms with | |||||||||
AND | doorless passageways or ventilation grills between the rooms. |
|
| ||||||
|
|
| |||||||
VENTILATION | 1. Determine the volume of the space (length x width x height). | ||||||||
Length x Width x Height = | ___________________ | cu. ft. (volume of space) | |||||||
Continued | |||||||||
Example: | Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = | ||||||||
|
| 2560 cu. ft. (volume of space) |
|
| |||||
| If additional ventilation to adjoining room is supplied with grills or openings, add the | ||||||||
| volume of these rooms to the total volume of the space. |
|
| ||||||
| 2. Divide the space volume by 50 cubic feet to determine the maximum BTU/Hr the space | ||||||||
| can support. |
|
|
|
|
|
|
| |
| ____________ (volume of space) ÷ 50 cu. ft. = (Maximum BTU/Hr | ||||||||
| the space can support) |
|
|
|
|
|
| ||
| Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = | 51.2 or 51,200 (maximum | |||||||
| BTU/Hr the space can support) |
|
|
|
|
|
| ||
| 3. Add the BTU/Hr of all fuel burning appliances in the space. | ||||||||
|
|
|
| ___________________ BTU/Hr | |||||
|
| Gas water heater* |
|
| ___________________ BTU/Hr | ||||
|
| Gas furnace |
|
|
| ___________________ BTU/Hr | |||
|
| Vented gas heater |
|
| ___________________ BTU/Hr | ||||
|
| Gas fireplace logs |
|
| ___________________ BTU/Hr | ||||
|
| Other gas appliances* | + ___________________ BTU/Hr | ||||||
|
| Total |
| = ___________________ BTU/Hr | |||||
| Example: | Gas water heater |
|
| 40,000 |
| BTU/Hr | ||
|
|
| + | 18,000 |
| BTU/Hr | |||
|
| Total |
| = |
|
|
| BTU/Hr | |
|
|
| 58,000 |
|
*Do not include
4.Compare the maximum BTU/Hr the space can support with the actual amount of BTU/ Hr used.
_________________ | BTU/Hr (maximum the space can support) |
_________________ | BTU/Hr (actual amount of BTU/Hr used) |
Example: 51,200 | BTU/Hr (maximum the space can support) |
58,000 | BTU/Hr (actual amount of BTU/Hr used) |
The space in the above example is a confined space because the actual BTU/Hr used is more than the maximum BTU/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.
B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 8.
C.Install a lower BTU/Hr heater, if lower BTU/Hr size makes room unconfined.
If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
WARNING
WARNING ICON | G 001 |
You must provide additional ventilation air in a confined space.
6
100751