Bradford-White Corp MI30T*F service manual Determine Water Temperature Inside Tank

Page 23

TheBradfordWhite

DEFENDER

Safety System®

SERVICE PROCEDURE RG-VI

Gas Control

Testing, Disassembly & Replacement (Honeywell)

WARNING

Stored water may be HOT when performing the following steps in this procedure.

Take necessary precaution to prevent personal injury.

DETERMINE WATER TEMPERATURE INSIDE TANK

Note: It is important to understand once the resistance for the temperature sensor is determined from the previous page, water flow through the water heater should not occur. Prior to drawing water from drain valve, turn off the cold water supply to the water heater. This will prevent cold water flow into the tank affecting the resistance value of the temperature sensor.

Step 1. Set the Gas Control knob to the “OFF” position. Step 2. Turn off inlet water supply to water heater.

Step 3. Draw approximately 4 gallons of water from drain valve into a container, or suitable drain, and discard. Draw an additional gallon and immediately measure water temperature using an accurate thermometer. It may be necessary to open a hot water faucet to allow water heater to drain.

Step 4. Using the chart below, determine correct resistance value for the water temperature from step 3.

Example:

If temperature of water is 84°F, then the resistance through the sensor would be

 

 

8449 (see shaded area). NOTE: Sensor resistance increases as the temperature

 

 

 

decreases.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor Resistance at Various Temperatures

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In Degrees F

 

 

 

 

 

 

 

°F

0

1

 

2

3

 

4

5

6

7

 

8

 

9

 

40

26109

25400

24712

24045

 

23399

22771

22163

21573

21000

 

20445

 

50

19906

19383

18876

18383

 

17905

17440

16990

16553

16128

 

15715

 

60

15314

14925

14548

14180

 

13823

13477

13140

12812

12494

 

12185

 

70

11884

11592

11308

11032

 

10763

10502

10248

10000

9760

 

9526

 

80

9299

9078

8862

8653

 

8449

8250

8057

7869

7685

 

7507

 

90

7333

7165

7000

6839

 

6683

6531

6383

6238

6098

 

5961

 

100

5827

5697

5570

5446

 

5326

5208

5094

4982

4873

 

4767

 

110

4663

4562

4464

4368

 

4274

4183

4094

4006

3922

 

3839

 

120

3758

3679

3602

3527

 

3453

3382

3312

3244

3177

 

3112

 

130

3048

2986

2925

2866

 

2808

2752

2697

2643

2590

 

2538

 

140

2488

2439

2391

2344

 

2298

2253

2209

2166

2124

 

2083

 

150

2043

2004

1966

1928

 

1891

1856

1820

1786

1753

 

1720

 

160

1688

1656

1625

1595

 

1566

1537

1509

1481

1454

 

1427

 

170

1402

1376

1351

1327

 

1303

1280

1257

1235

1213

 

1191

 

180

1170

1150

1129

1110

 

1090

1071

1953

1035

1017

 

999

 

190

982

965

 

949

933

 

917

901

886

871

857

 

842

 

200

828

814

 

801

788

 

775

762

749

737

725

 

713

23

23

Image 23
Contents Service Manual Bradford White Introduction White Rodgers/Robertshaw Gas Valve Troubleshooting Chart Honeywell Gas Control Troubleshooting Chart Honeywell Gas Control Troubleshooting Chart Defender Installation of Inner Door With Gasket Combustion chamber Closed Circuit Thermocouple Testing Robertshaw Control Closed Circuit Thermocouple Testing White Rodgers ControlThermocouple Replacement White Rodgers/Robertshaw Gas Valve Open Circuit Thermopile Testing Honeywell Gas Control PILOT/ELECTRODE Assembly Inspection Cleaning and Replacement Defender Piezo IGNITER, Electrode Testing and ReplacementLine Pressure Gas Valve Testing and Replacement White Rodgers/RobertshawMagnet Assembly Testing Robertshaw Control Thermocouple TestingMagnet Assembly Testing White Rodgers Control Combination THERMOSTAT/GAS Valve Replacement ECO Energy Cut Off TestingWrench Boss Position thermocouple, pilot tube and Piezo wire Honeywell Gas Control Testing, Disassembly, and Replacement Thermopile Testing Defender Temperature Sensor TestingSensor Resistance at Various Temperatures Determine Water Temperature Inside TankGAS Control DISASSEMBLY/REASSEMBLY Temperature sensor Wire routing clip Disconnect Use caution not to bend or damage valve body pins Pull in this direction Temperature sensor Insertion stick GAS Control Replacement Defender Combustion chamber Cast Iron Burner Adjustment Main Burner Inspection, Adjustment Cleaning and ReplacementPosition thermocouple/thermopile Pilot tube and Piezo wire Burner Cleaning Resettable Thermal Switch Continuity Testing Over Tighten Screws Resettable Thermal Switch ReplacementFeedline Nut ScreenLok Flame Arrestor CleaningDIP Tube Inspection and Replacement Anode Inspection and Replacement Generic Parts List Parts@bradfordwhite.com Techserv@bradfordwhite.com