STATUS LIGHT CODE TROUBLESHOOTING TABLE
Status Light Code
LED FLASH | CONTROL STATUS |
| CORRECTIVE ACTION |
SEQUENCE |
|
|
|
Soft Lockout - Recycle Limit - Flame Lost - | Turn the power switch on the gas control valve to the “OFF” position and unplug the power cord from the | ||
| END Switch Fails | power outlet. | |
| 1. | Check all wiring connections to insure all harness and wire connections are seated firmly and provide | |
|
| ||
|
|
| proper electrical contact. If no connection problems are found replace the damper. Firmly seat any |
|
|
| loose connections found. If any connections are found to be damaged consult the replacement parts |
|
|
| list on pages |
|
|
| the water heater by following the lighting instructions on page 16. If the problem persists replace the |
|
|
| damper. |
Soft Lockout - Recycle Limit - Flame Lost | Turn the power switch on the gas control valve to the “OFF” position and unplug the power cord from the | ||
|
| power outlet. | |
|
| 1. | Check the incoming gas line pressure to ensure adequate supply to the water heater. If incoming |
|
|
| gas supply pressure is adequate proceed to step 2. |
|
| 2. | Check all wiring connections and insure all harness and wires connections are seated firmly and |
|
|
| provide proper electrical contact. If no connection problems are found proceed to step 3. Firmly |
|
|
| seat any loose connections found. If any connections are found to be damaged consult the |
|
|
| replacement parts list for the appropriate replacement. After any connection problems are fixed |
|
|
| restart the water heater by following the lighting instructions on page 16. If the problem persists |
|
|
| proceed to step 3. |
|
| 3. | Check condition of the base ring filter and flame arrestor. If they are clogged follow the instruc- |
|
|
| tions for cleaning on page #. If parts are not clogged proceed to step 4. After cleaning follow |
|
|
| instructions for lighting on page 16. If problem persists proceed to step 4. |
|
| 4. | Follow the instructions on page # to remove the burner assembly. Once the burner assembly has |
|
|
| been removed inspect the manifold tube and burner, see figure 29 , for any obstructions. If any |
|
|
| clogs or obstructions are present clear them. Inspect the electrode/flame sense rod, see figure |
|
|
| # , for corrosion buildup, degradation, or damage. If there is evidence of any damage to the |
|
|
| electrode/flame sense rod replace the igniter/pilot assembly. Follow the directions on page 25 to |
|
|
| |
|
|
| page 16. If the problem persists contact a certified service representative. |
Soft Lockout - Flame out of Sequence Sensed | Turn the power switch on the gas control valve to the “OFF” position and unplug the power cord from the | ||
|
| power outlet. Wait 10 minutes then follow the lighting instructions on page 16. If the problem persists | |
|
| replace the gas control valve. | |
Seven Flash, three second pause | Flammable Vapor Sensor (FVS) Lockout | 1. | Do not touch any electrical switch, do not use any phone in the building and do not try to light any |
|
|
| appliance. |
|
| 2. | Smell around the water heater to ensure there are no gas leaks at the gas control valve or in the |
|
|
| supply gas line or for any other type of flammable vapors in the area. |
|
| 3. | Carefully inspect the area surrounding the water heater for any substances such as gasoline, |
|
|
| paint, paint thinners, varnish, or cleaners that could emit flammable vapors. Remove anything that |
|
|
| can potentially emit flammable vapors from the area and store it properly in a different location. |
|
| 4. | Contact a certified service representative for inspection. |
|
|
| |
Flammable Vapor Sensor (FVS) Fault Detected | Turn the power switch on the gas control valve to the “OFF” position, wait | ||
|
| power switch on the gas control valve to the “ON” position. If the problem persists replace the gas valve. | |
|
|
| |
Temperature Sensor Fault Detected | Turn the power switch on the gas control valve to the “OFF” position, wait | ||
|
| power switch on the gas control valve to the “ON” position. If the problem persists replace the gas valve. | |
|
|
| |
Electronic Fault Detected | Turn the power switch on the gas control valve to the “OFF” position, wait | ||
|
| power switch on the gas control valve to the “ON” position. If the problem persists replace the gas valve. | |
|
|
| |
Gas Control Valve/Thermostat Fault Detected | Turn the power switch on the gas control valve to the “OFF” position, wait | ||
|
| power switch on the gas control valve to the “ON” position. If the problem persists replace the gas valve. | |