American Water Heater ABCG3 Precautions Hydrogen Gas Flammable, Grounding Instructions

Page 5

General Safety Information

Read and understand this instruction manual and the safety messages herein before installing, operating or servicing this water heater.

Failure to follow these instructions and safety messages could result in death or serious injury.

This manual must remain with the water heater.

Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death.

Children, the elderly and the physically or mentally disabled are at highest risk for scald injury.

Feel water before bathing or showering.

Temperature limiting devices such as mixing valves must be installed when required by codes and to ensure safe temperatures at fixtures.

Explosion Hazard

Overheated water can cause water tank explosion.

Properly sized temperature and

pressure relief valve must be installed in the opening provided.

CAUTION

Improper installation, use and service may result

in property damage.

Do not operate water heater if flood damaged.

Inspect and anode rods regularly, replace if damaged.

Install in location with drainage.

Fill tank with water before operation.

Properly sized thermal expansion tanks are required on all closed water systems.

Refer to this manual for installation and service.

Verify the power to the water heater is turned off before performing any service procedures.

 

General Safety Information

 

Precautions

 

 

Hydrogen Gas Flammable

 

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. Immediately call a qualified service agency to inspect the appliance and to make a determination on what steps should be taken next.

If the unit is exposed to the following, do not operate heater until all corrective steps have been made by a qualified service agency.

1.External fire.

2.Damage.

3.Firing without water.

Grounding Instructions

This water heater must be grounded in accordance with the National Electrical Code and/or local codes. These must be followed in all cases.

This water heater must be connected to a grounded permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the water heater, see Figure 20.

Explosion Hazard

Flammable hydrogen gases may be present.

Keep all ignition sources away from faucet when turning on hot water.

Hydrogen gas can be produced in a hot water system served by this appliance that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that a hot water faucet served by this appliance be opened for several minutes before using any electrical appliance connected to the hot water system. If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open.

5

Image 5
Contents Commercial gas water heaters Table Of Contents Approvals Safe Installation, Use and ServiceFire and Explosion Hazard General Safety InformationGrounding Instructions Precautions Hydrogen Gas FlammableIntroduction Qualified Installer or Service AgencyAbbreviations Used QualificationsHigh Limit Switch Eliminator self-cleaning systemLow Gas Pressure Switch Electronic Ignition ControlRough In Dimensions Installation considerationsROUGH-IN-DIMENSIONS Recovery CAPACITIES, based on 80% efficiencyClearances Locating the Water HeaterCirculation pumps Installation on Combustible FlooringInsulation Blanket High Altitude Installations Installation Requirements Dishwashing Machines Temperature-Pressure Relief ValveClosed Water Systems Thermal ExpansionValve Discharge Pipe Requirements Contaminated AirAir Requirements Venting Unconfined SpaceConfined Space Fresh Air Openings for Confined Spaces Multiple Heater ManifoldOutdoor Air Through Two Openings Outdoor Air Through One OpeningAir From Other Indoor Spaces Outdoor Air Through Two Vertical DuctsMultiple Gas Fired Tank-Type Heaters Technical Data VentingTechnical Data Venting Valve Discharge Pipe Water heater installationWater Line Connections Tube Inlet Installation Installation Diagrams Top Inlet/Outlet UsageHeater Wiring Gas Piping Gas Line Leak TestingPurging Gas Meter Size Natural Gases OnlyInitial Start Up Start UpPrior to Start Up Checking Venting Water Temperature AdjustmentGas Valves Checking the InputLighting & Operation Label Sequence of OperationSequence of Operation Flow Chart Maintenance Anode Rod Inspection Hot Water OdorDraining and Flushing To Drain the Water Heater Storage TankDeliming Using FLO-JUG Method Tank Cleanout ProcedureDeliming Solvents ExampleChemical Hazard Electrical Servicing System DiagnosticsIgnition Module System For Your Information High Water Temperature Shut Off SystemStart Up Conditions Operational ConditionsComplaint Cause Remedy User TroubleshootingQualified Service Agency Water Piping DiagramsTemperature & Pressure Temperature & Pressure Relief Valve Circulating Pump Multi Flue 2 Units Multi Flue 2 Units with Vertical Storage Tank Multi Flue 2 Units with Vertical Storage Tank Return from Multi Flue 2 Units TWO Temperature Multi Flue 2 Units with Booster TWO Temperature MULTI-FLUE 3 Units MULTI-FLUE 3 Units with Vertical Storage Tank MULTI-FLUE 3 Units with Horizontal Storage Tank Multi Flue Flue 4 Units MULTI-FLUE 4 Units with Vertical Storage Tank MULTI-FLUE 4 Units with Horizontal Storage Tank Manifold Kits Claim Procedure Service and Repair ExpensesALL Other Parts Conditions and Exceptions