American Water Heater BCG3 Installation considerations, Rough In Dimensions, Rough-In-Dimensions

Page 8

Installation considerations

Rough In Dimensions

TOP

 

F

 

TOP

OUTLET

 

 

INLET

 

 

1 1/2” NPT

 

 

 

1 1/2” NPT

TOP VIEW

FIGURE 5.

FRONT VIEWBACK VIEW

TABLE 1. ROUGH-IN-DIMENSIONS

Model

BCG3 70T120 5NOX

BCG3 80T150 6NOX

BCG3 100T180 6NOX

BCG3 95T199 6NOX

BCG3100T199 6NOX

BCG3 100T200 6NOX

BCG3 100T250 6NOX

BCG3 100T275 6NOX

BCG3 85T310 6NOX

BCG3 85T366 6NOX

BCG3 85T390 6NOX

Dim.

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

A

63

1800

68

1727

72

1829

72

1829

72

1829

72

1829

72

1829

72

1829

73

1854

73

1854

73

1854

B

4 1/4

108

4 1/2

114

4 1/2

114

4 1/2

114

4 1/2

114

4 1/2

114

4 1/2

114

4 1/2

114

41/2

114

4 1/2

114

4 1/2

114

C

59 1/2

1511

62

1575

70

1778

70

1778

70

1778

70

1778

70

1778

70

1778

72

1829

72

1829

72

1829

D

50 7/8

1292

53 5/8

1362

61 5/8

1565

61 5/8

1565

61 5/8

1565

61 5/8

1565

61 5/8

1565

61 5/8

1565

62 1/2

1588

62 1/2

1588

62 1/2

1588

E

19 11/16

500

20 1/2

521

20 1/2

521

20 1/2

521

20 1/2

521

20 1/2

521

20 1/2

521

20 1/2

521

22 1/2

572

22 1/2

572

22 1/2

572

F

19

483

21

533

21

533

21

533

21

533

21

533

21

533

21

533

21

533

21

533

21

533

G

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

1 NPT

1 NPT

H

51 7/8

1318

54 5/8

1387

61

1549

61

1549

61

1549

61

1549

61

1549

61

1549

63

1600

63

1600

63

1600

I

5

127

6

152

6

152

6

152

6

152

6

152

6

152

6

152

6

152

6

152

6

152

J

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

K

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

2 NPT

2 NPT

2 NPT

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

L

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

2 NPT

2 NPT

2 NPT

1 1/2 NPT

1 1/2 NPT

1 1/2 NPT

Approx.

 

236

550

 

550

249

620

281

550

249

660

299

660

299

660

299

720

327

830

 

830

376

Shipping

520 Ibs.

249 Kg.

376 Kg.

Weight

 

Kg.

Ibs.

 

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Kg.

Ibs.

 

Ibs.

Kg.

STD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approx.

 

 

 

 

 

 

 

 

 

 

710

322

710

322

710

322

770

349

880

 

880

399

Shipping

 

 

 

 

 

 

 

 

 

 

399 Kg.

Weight

 

 

 

 

 

 

 

 

 

 

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Kg.

Ibs.

Ibs.

Kg.

 

 

 

 

 

 

 

 

 

 

 

ASME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 2. RECOVERY CAPACITIES, based on 80% efficiency

 

Input

Input

U.S.

Liters

Eff. %

 

 

 

 

U. S. Gallons/Hr. and Liters/Hr. at TEMPERATURE RISE INDICATED

 

 

 

 

 

Deg. F

36

40

50

54

60

70

72

80

90

100

108

110

120

126

130

140

 

BTUH

KW

Gal.

 

 

Deg. C

20

22

28

30

33

39

40

44

50

56

60

61

67

70

72

78

 

 

 

 

 

 

BCG3 70T120 5NOX

120000

 

71

 

80

GPH

321

289

231

214

192

165

160

144

128

115

107

105

96

92

89

82

 

35

 

269

LPH

1214

1093

874

810

729

625

607

546

486

437

405

397

364

347

336

312

 

 

 

 

BCG3 80T150 6NOX

154000

 

81

 

80

GPH

412

371

296

274

247

212

206

185

165

148

137

135

124

118

114

106

 

45

 

307

LPH

1559

1403

1122

1039

935

802

779

701

623

561

520

510

468

445

432

401

 

 

 

 

BCG3 100T180 6NOX

180000

 

100

 

80

GPH

481

433

346

321

289

247

241

217

192

173

160

157

144

137

133

124

 

53

 

379

LPH

1822

1639

1312

1214

1093

937

911

820

729

656

607

596

546

520

504

468

 

 

 

 

BCG3 95T199 6NOX

199000

 

93

 

80

GPH

532

479

383

355

319

274

266

239

213

192

177

174

160

152

147

137

 

58

 

352

LPH

2014

1813

1450

1343

1208

1036

1007

906

806

725

671

659

604

575

558

518

 

 

 

 

BCG3 100T199 6NOX

199000

 

100

 

80

GPH

532

479

383

355

319

274

266

239

213

192

177

174

160

152

147

137

 

58

 

379

LPH

2014

1813

1450

1343

1208

1036

1007

906

806

725

671

659

604

575

558

518

 

 

 

 

BCG3 100T200 6NOX

199000

 

100

 

80

GPH

532

479

383

355

319

274

266

239

213

192

177

174

160

152

147

137

 

58

 

379

LPH

2014

1813

1450

1343

1208

1036

1007

906

806

725

671

659

604

575

558

518

 

 

 

 

BCG3 100T250 6NOX

250000

 

100

 

80

GPH

668

602

481

446

401

344

334

301

267

241

223

219

201

191

185

172

 

73

 

379

LPH

2530

2277

1822

1687

1518

1301

1265

1139

1012

911

843

828

759

723

701

651

 

 

 

 

BCG3 100T275 6NOX

275000

 

100

 

80

GPH

735

662

529

490

441

378

368

331

294

265

245

241

221

210

204

189

 

81

 

379

LPH

2783

2505

2004

1855

1670

1431

1392

1252

1113

1002

928

911

835

795

771

716

 

 

 

 

BCG3 85T310 6NOX

310000

 

85

 

80

GPH

829

746

597

553

497

426

414

373

332

298

276

271

249

237

230

213

 

91

 

322

LPH

3137

2824

2259

2092

1882

1613

1569

1412

1255

1129

1046

1027

941

896

869

807

 

 

 

 

BCG3 85T366 6NOX

366000

 

85

 

80

GPH

978

881

705

652

587

503

489

440

391

352

326

320

294

280

271

252

 

107

 

322

LPH

3704

3334

2667

2469

2222

1905

1852

1667

1482

1333

1235

1212

1111

1058

1026

952

 

 

 

 

BCG3 85T390 6NOX

390000

 

85

 

80

GPH

1043

938

751

695

626

536

521

469

417

375

348

341

313

298

289

268

 

114

 

322

LPH

3947

3552

2842

2631

2368

2030

1973

1776

1579

1421

1316

1292

1184

1128

1093

1015

 

 

 

 

TABLE 3. GAS AND ELECTRICAL CHARACTERISTICS

 

 

Gas Supply Pressure

 

 

 

Model

Type of Gas

Minimum

Maximum

Gas Manifold Pressure

Volts/Hz

Amperes

All Models

Natural

5.2" W.C. (1.3 kPa)

14" W.C. (3.48 kPa)

3.5" W.C. (0.87 kPa)

120/60

<5

 

 

 

 

 

 

 

8

Image 8
Contents Commercial gas water heaters Table Of Contents Safe Installation, Use and Service ApprovalsGeneral Safety Information Fire and Explosion Hazard Precautions Hydrogen Gas Flammable Grounding InstructionsQualified Installer or Service Agency IntroductionAbbreviations Used QualificationsEliminator self-cleaning system High Limit SwitchLow Gas Pressure Switch Electronic Ignition ControlInstallation considerations Rough In DimensionsROUGH-IN-DIMENSIONS Recovery CAPACITIES, based on 80% efficiencyLocating the Water Heater ClearancesCirculation pumps Installation on Combustible FlooringInsulation Blanket High Altitude Installations Installation Requirements Temperature-Pressure Relief Valve Dishwashing MachinesClosed Water Systems Thermal ExpansionValve Discharge Pipe Requirements Contaminated AirAir Requirements Venting Unconfined SpaceConfined Space Multiple Heater Manifold Fresh Air Openings for Confined SpacesOutdoor Air Through Two Openings Outdoor Air Through One OpeningOutdoor Air Through Two Vertical Ducts Air From Other Indoor SpacesTechnical Data Venting Multiple Gas Fired Tank-Type HeatersTechnical Data Venting Valve Discharge Pipe Water heater installationWater Line Connections Installation Diagrams Top Inlet/Outlet Usage Tube Inlet InstallationHeater Wiring Gas Line Leak Testing Gas PipingPurging Gas Meter Size Natural Gases OnlyInitial Start Up Start UpPrior to Start Up Water Temperature Adjustment Checking VentingGas Valves Checking the InputSequence of Operation Lighting & Operation LabelSequence of Operation Flow Chart Maintenance Hot Water Odor Anode Rod InspectionDraining and Flushing To Drain the Water Heater Storage TankTank Cleanout Procedure Deliming Using FLO-JUG MethodDeliming Solvents ExampleChemical Hazard Electrical Servicing System DiagnosticsIgnition Module System High Water Temperature Shut Off System For Your InformationStart Up Conditions Operational ConditionsComplaint Cause Remedy User TroubleshootingQualified Service Agency Diagrams Water PipingTemperature & Pressure Temperature & Pressure Relief Valve Circulating Pump Multi Flue 2 Units Multi Flue 2 Units with Vertical Storage Tank Multi Flue 2 Units with Vertical Storage Tank Return from Multi Flue 2 Units TWO Temperature Multi Flue 2 Units with Booster TWO Temperature MULTI-FLUE 3 Units MULTI-FLUE 3 Units with Vertical Storage Tank MULTI-FLUE 3 Units with Horizontal Storage Tank Multi Flue Flue 4 Units MULTI-FLUE 4 Units with Vertical Storage Tank MULTI-FLUE 4 Units with Horizontal Storage Tank Manifold Kits Service and Repair Expenses Claim ProcedureALL Other Parts Conditions and Exceptions