Genie 4024H manual Adjustment Guide Force Settings, Change Force Setting

Page 23

ADJUSTMENT GUIDE - FORCE SETTINGS

CAUTION

Door closing force is FACTORY set and requires no adjustment for normal operation.

Never increase the door closing force to compensate for a damaged door or a binding door track.

Never adjust force to compensate for a broken door spring.

Perform monthly CONTACT REVERSE TEST as described on page 18.

Force settings are pre-programmed at the factory and "learned" during the Open/Close Limit settings steps. Some additional Force may be increased. For normal use, Force settings should not need adjustment with this unit.

However, conditions that might suggest an adjustment is necessary are;

Doors with very stiff weather seals.

Doors that start down, then STOP and reverse before they close.

Doors that start up, but STOP before they completely open.

FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM

CHANGE FORCE SETTING

Use this guide to ADJUST powerhead FORCE settings. NOTE: There are nine (9) force levels.

PROGRAM

1.Press on the powerhead and hold until both

SET

lights turn steady ON. Release button.

Lights go out and Round BLUE light comes ON.

2.Press three times, Round RED light comes ON.

PROGRAM

3.Press once to enter the Force Programming

SET

menu. The round LED will flash BLUE 3 times, then the current Force setting for UP force will display on the LEDs. See table below.

4.(If current UP Force setting is good, skip to Step

5.) Press to increase or to decrease UP Force

settings within the available range.

PROGRAM

5.Press to set UP Force level. The long LED will

SET

flash BLUE 3 times, then the current Force setting for DOWN force will display on the LEDs.

6.(If current DOWN Force setting is good, skip to Step 7.) Press to increase or to decrease

DOWN Force settings within the available range.

PROGRAM

7.Press SET to set DOWN Force level. Both LEDs flash BLUE to confirm.

Force Level

Powerhead LEDs

Round LED Long LED

Default LED display is the current Force setting

LED indicator colors

OFF,

Blue,

Purple,

Red

Force Level LED indicator colors

Force Level 1

Force Level 2

Force Level 3

Force Level 4

Force Level 5

Force Level 6

Force Level 7

Force Level 8

Force Level 9

Blue

OFF

ON

 

OFF

Blue

ON

 

Blue

Blue

ON

ON

Purple

OFF

ON

 

OFF

Purple

ON

 

Purple

Purple

ON

ON

Red

OFF

ON

 

OFF

Red

ON

 

Red

Red

ON

ON

©2010 The Genie Company

12/2010

23

Image 23
Contents Operation and Maintenance Manual Prevention Potential HazardSafety Features Opener FeaturesTable of Contents Infrared Protection Function Important Installation InstructionsClose Door Travel Limit Programming Limits & ForceBoth LEDs flash Blue Go OFF Open Door Travel LimitSee long Blue LED flashing Door Limits are setTest AdjustmentSee round Blue LED come on Bring remotes to powerhead locationSee long Purple LED flashing IntelliCode 1 remotesSee long Purple LED flashing + see both LEDs Flash Purple Genie IntelliCode 1 wireless keypadGenie IntelliCode 1 remote See onePower Head Tête DE Puissance Cabeza DE LA Energía Reference Powerhead & Rail Assembled ViewInstallation Typique SUR UNE Porte Sectionelle Typical ONE Piece Door Installation Programming Buttons location Overview of Powerhead ControlsOn powerhead Hold Overview Remotes and OptionsIntellicode Features Transmitter Compliance Statement Maintenance & TroubleshootingDoor Balance Spring Tension Routine Monthly MaintenanceAdjustment Safe-T-Beam System Check Door balance Contact reverseMotion DETECTOR* Overview Reset OPEN/CLOSE Travel LimitDoor Change Light BulbsClosed Unlock allows controls to work normally Wire routingWall Console Overview Open and closes door from inside garageChain Chain or Belt Tension AdjustmentRemote Battery Replacement BeltPowerhead LEDs Round LED Long LED Adjustment Guide Speed SettingsChange Speed Setting Change Force Setting Adjustment Guide Force SettingsTroubleshooting Guide Operation Powerhead LED Possible Problem Solution Opening Cover May Cause Electric Shock Reference Circuit Wiring DiagramLimited Warranty